Mitsubishi Electric FR-V500 Instruction Manual page 214

High precision & fast response vector inverter
Hide thumbs Also See for FR-V500:
Table of Contents

Advertisement

(2) Encoder connector (Manufactured by Japan Aviation Electronics Industries) for
reference
Straight Plug MS3106B20-29S
1-1/4-18UNEF-2B
18.3
55.6
1-3/16-18UNEF-2B
(3) Cable stresses
(1) The way of clamping the cable must be fully
considered so that flexing stress and cable's own
weight stress are not applied to the cable
connection.
(2) In any application where the motor moves, do not
subject the cable to excessive stress.
(3) Avoid any probability that the cable sheath might
be cut by sharp chips, rubbed by a machine corner
or trampled over by workers or vehicles.
(4) The reference value of dedicated encoder cable
flexing life is shown on the right.
When mounting the encoder on a machine where
the motor will move, the flexing radius should be as
large as possible.
1-3/16-18UNEF-2A
9.5
Effective screw length
Cable Clamp MS3057-12A
23.8
10.3
1.6
205
Outline dimension drawings
Angle Plug MS3108B20-29S
Positioning keyway
1-3/16-18
UNEF-2A
Effective screw length
Note
This angle type connector is not optional. Please obtain it
separately.
φ
10
φ
10
4
7
1 × 10
6
5 × 10
6
2 × 10
6
1 × 10
5
5 × 10
5
2 × 10
5
1 × 10
4
7 × 10
4
5 × 10
4
3 × 10
5 7 10
20
Bending radius [mm]
CAUTION
This graph shows calculated values and not
guaranteed values.
1-1/4-18UNEF-2B
18.3
φ
23
60.7
77
maximum allowable
cable diameter
Standard product
FR-VCBL
FR-JCBL
40 70 100 200
500
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-v520Fr-v540