7.1.2

Transport and Installation

The manufacturer does not assume liability for any damage, complaints or missing parts which are not reported
N
immediately upon delivery on the packing list/delivery note.
In order to ensure proper installation and safety, the manufacturer, an authorised service crew or an authorised
N
dealer must always transport and install the devices.
Failure to comply with the conditions listed in this operation and service manual and listed in the operation and
N
service manuals of other respective devices which may be used in connection with this device, failure of
performing recommended maintenance and safety inspection intervals, unauthorized maintenance or amendments
of the design and/or performance and/or specifications and/or labelling of the devices shall absolve h/p/cosmos
sports & medical gmbh from any responsibility for the safety, reliability and performance of this equipment.
Always ground (earth) the device to prevent electric shock. If the power supply outlet is not grounded, it will be
N
necessary to install a ground by qualified engineers.
Never ground the device through a gas pipe, water main, telephone line or lightning rod. Such grounding may
N
cause electric shock in the case of an incomplete circuit.
Connect the device to a power source as indicated on the name plate (rating label) attached to the unit. Use of any
N
other voltage or frequency other than that on the name plate may cause fire or electric shock or may cause other
damages.
Plug the running machines directly into the wall socket with a protection system. Each running machine should be
N
connected to a separate circuit. The socket is to be marked with name and serial number of the running machine.
The use of extension cables or a multiple plug socket is prohibited.
An overload or voltage drop (even temporary) of more than 20 % of the mains voltage might cause malfunctions
N
and/or defects and might totally switch-off the running machine. In the event of such high voltage drops or total
power failure, the running machine switches off and the running belt stops. To start again, switch on the running
machine at the main „ON" switch and then press START on the keyboard.
When connecting treadmills to the multiple safety socket, there are no performance limitations to expect at low-
N
performance applications (walking, slow running). For high-performance applications (fast running, sprints, etc.,)
the use of the multiple safety socket can result in performance limitations.
For treadmills used in the medical field:
N
All devices are to be connected via a potential compensation cable in „star connection" with the potential
N
compensation bar.
First connect the potential compensation (potential equalization) with the corresponding plug pin (next to the
N
main switch on the front) and then connect the mains plug.
During electric safety measurements and tests (leakage currents, etc.) the potential equalization cable has to
N
be disconnected temporarily.
Due to the very high electrical load of treadmills, do not connect more than one treadmill or
N
device with high load to the multiple safety socket. Use a dedicated line only.
After adjusting the running belt, the allen key must be pulled out of the screw immediately after usage due to risk of
N
injury!
There are dangerous capture areas/gaps at the elevation system as well as at the rear end and the sides of the
N
running belt. At reverse belt rotation there is also danger at the motor hood and front area.
It should be ensured that all cables (power connection, interface, potential equalization, etc.) and accessories are
N
installed properly and safely and that nobody can stumble or fall over the cables and/or accessories.
The connection of the gas pressure container has to be checked for MOT-admissibility (TÜV).
N
Absorption, cleaning and disinfecting chemicals are to be kept in the appropriate reservoirs.
N
All lubrication material and all other parts should be kept away from children and animals.
N
© 2013 h/p/cosmos sports & medical gmbh
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
author: fh
email@h-p-cosmos.com
safety, installation and commissioning
created 07.02.2013
printed 04.03.2013
page: 80 of 197