External Userterminal Control Unit - h/p/cosmos 150/50 Operating And Service Manual

Table of Contents

Advertisement

operation
5.5.3

External UserTerminal control unit

Running machines with running surface size 200/75cm upwards have to be started using the main switch (further
descriptions chapter "switch on procedure").
elevation speed
Switch for slow or fast change of elevation
(fast: switch is blue lighted)
belt direction
Switch for forward / backward running
(backward: switch is blue lighted)
belt alignment – adjust it!
Running belt is moving outside tolerance range.
yellow lighted: belt out of tolerance
yellow blinking: belt severe out of tolerance
check power supply!
Power supply too high or low
or phase breakdown
Check only by trained and authorized technician
oil tank empty
Refill oil tank (see chapter 8.4.5)
light barrier / quick stop active
One or more safety features activated:
check light barrier front/back, safety arch and
further safety features
switch on delay
For protection of electric components the green
indicator is blinking for 1min. until device can be
started (indicator is green lighted)
"on"-button
Switches the device on
(only possible after switch on delay)
"off"-button
Switches the device off
(green indicator is blinking for 1 min.)
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
© 2013 h/p/cosmos sports & medical gmbh
author: fh
email@h-p-cosmos.com
created 07.02.2013
printed 04.03.2013
page: 35 of 197

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Venus 200/75450/300200/75170/65190/65

Table of Contents