Trouble Shooting; Mechanical Noise Problems; Running Belt Adjustment Problems; Fuses - h/p/cosmos 150/50 Operating And Service Manual

Table of Contents

Advertisement

9 Trouble shooting

In case of a detected and/or assumed malfunction and/or defects or unreadable safety warning label,
disengage the device immediately and mark it as such. Furthermore, secure the device against further
operation and inform the supplier and authorised service personnel in writing.
See OP40 in chapter 5.10 entitled "Optional settings: User Options: With OP 41 ... 44 you can also lock
separate modes (manual, profile, cardio, test).

9.1 Mechanical noise problems

If knocking or rattling noises are heard during training, please check if the machine has a firm stand and follow exactly
the advice given in the chapter 7.4.5 "Mechanical installation". Most often false adjustment of the levelling sockets
(adjustable "feet") at the rear of the running machine is responsible for the knocking sound.

9.2 Running belt adjustment problems

If the tension of the running belt is not correct, it is difficult to keep the position of the belt centred. The belt should be re-
adjusted every time it is used in reverse direction mode. Check and follow exactly the advice in the chapter 8.5 entitled
"Control and tightening of the running belt"

9.3 Fuses

Expulsion fuse/ON-OFF button 2-pole C16A
Secondary fuse isolation transformer 1-pole B16A
Expulsion fuse on devices with external switching cabinet
© 2013 h/p/cosmos sports & medical gmbh
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
author: fh
email@h-p-cosmos.com
Expulsion fuse, device fuse 3-pole C16A
Secondary fuse isolation transformer 3-pole C16A
Fuses in cabinet for power supply unit
created 07.02.2013
printed 04.03.2013
trouble shooting