Resetting Of Oil Message; Control And Tightening Of The Running Belt - h/p/cosmos 150/50 Operating And Service Manual

Table of Contents

Advertisement

8.4.6

Resetting of oil message

An external UserTerminal or the PC-software h/p/cosmos para control
UserTerminal.
Initiation: running belt is not moving. One of the mode LEDs  is flashing: manual, profile, cardio, test
Step
Activity
[01]
Select of the mode for "user
options" (OPxx)
[02]
Confirm option no. 1
[03]
Delete message
[04]
Quit option mode

8.5 Control and tightening of the running belt

The belt may loosen after a while or if it has been adjusted wrongly. In this case a backlash occurs between the driving
shaft and the belt, i.e. when weight is applied to the belt by stepping on it, the belt slows down.
If the running belt is blocked too long, the motor regulation can switch off because of excess
current, which will be indicated by an error display. In this case, switch off the device for 5 minutes
and then switch it on again. The belt tension should not be more than 0.5 %, otherwise it could
damage the belt, the shafts or the bearings!
© 2013 h/p/cosmos sports & medical gmbh
Keys
a d b
press 3 keys
simultaneously for
at least 3 seconds
c
c
b
The belt tension should be checked as follows:
Visually inspect the surface for cracks. In case of a crack replace
N
running belt immediately.
Open the motor hood at the front. Take care that nobody gets his
N
hands into the motor.
Press the "START/Enter" key for manual mode and select a
N
speed of 1 to 1.5 km/h with the help of the "+"/"-" keys.
Stand on the running belt. Hold on to the side handrails with both
N
hands and try to block the rotation of the running belt by
stemming yourself against the belt with your feet. If necessary, 2
people can do this.
Try to block the movement of the running belt for max. 10
N
seconds. The driving shaft and the motor shaft should not be
turning during that time. Otherwise the running belt has to be
tightened (or the driving belt).
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
author: fh
email@h-p-cosmos.com
maintenance and safety inspections
is required for devices without
®
Response/Display
=
indicates: OP01 flashing (for option no. 01)
!
"
and
indicate: E.rE SEt (for error reset)
§
indicates "donE" to inform you that the oil
message must be deleted.
=
indicates: OP01 flashing (for option no. 01)
!
"
and
indicate: E.rE SEt (for error reset)
Stand-by mode
manual, profile, cardio or test is flashing
created 07.02.2013
printed 04.03.2013
page: 118 of 197