SYSTEM SETUP
SYSTEM SETUP
DISPLAY : MONITOR
SEQUENCE DWELL : The time that each screen is displayed in a sequence operation.
SPOT-OUT DWELL : The time that each screen is displayed on the spot monitor outputs.
DE-INTERLACE MODE : When recording any channels in D1 resolution (704 x 480) this should be set to
ALARM POP-UP MODE : When set to ON, an alarm input will cause the associated channel to display
ALARM POP-UP DWELL : Determines how long the full screen popup is displayed after an alarm input.
MOTION POP-UP MODE : When set to ON, motion detection will cause the associated channel to display
MOTION POP-UP DWELL : Determines how long the full screen popup is displayed after motion detection.
DISPLAY MODE : The DVR output can be optimized for display on a VGA or AV (CRT) monitor.
To change any of these settings, highlight MONITOR and press
Use the
CURSOR KEYS
changes
to
yellow) and use the
or
PREVIOUS
to cancel.
Note: When changing between display modes, you must shutdown and restart the DVR before
any changes will take effect.
ON to
prevent motion distortion during playback.
full screen.
If the alarm condition continues, the popup screen is displayed constantly.
full screen.
If motion continues, the popup screen is displayed constantly.
to navigate to the option required. Press
CURSOR KEYS
Click the MONITOR menu. Click on a field to
change its setting.
Then click the
ENTER
ENTER
to change the setting. Press
23
button to toggle the setting.
to select.
to select the option (the cursor
APPLY
to save the setting