Communication
6.5 Communication via PROFINET
6.5.4

PROFInet Configuration Example with SIMATIC S7

Prerequisites
To integrate a SINAMICS G120 inverter in SIMATIC S7 control system, the following
requirements should be fulfilled:
Prerequisites for standard inverters
● STEP 7 V5.4, SP1 is installed on the engineering station
● In HW Config, the following components are disposed:
Prerequisites for PROFIsafe via Profinet
● STEP 7 V5.4, SP2 is installed on the engineering station
● In HW Config, the following components are disposed:
If the G120 is not available, the GSDML V2.0 has to be installed. It can be downloaded and
installed from the internet under the following link:
http://support.automation.siemens.com/WW/view/de/22339653/133100
Installing the GSDML V2.0 file
1. Save the GSDML V2.0 file on your system and save the path.
2. Choose in the menu "Options > Install GSD File".
3. Add the relevant path to the GSDML V2.0 file and confirm with OK.
170
– One of the following CPUs
CPU 315-2 PN/DP with firmware at least 2.5.1
CPU 317-2 PN/DP with firmware at least 2.5.1
CPU 319-3 PN/DP
– A SIMATIC control system with a PROFINET sub-network, e.g. SIMATIC 300
– SINAMICS G120 inverters are available as PROFINET I/O device in the hardware
catalog.
– One of the following CPUs
CPU 315F-2 PN/DP with firmware at least 2.5.1
CPU 317F-2 PN/DP with firmware at least 2.5.1
CPU 319F-3 PN/DP
– A SIMATIC control system with a PROFINET sub-network, e.g. SIMATIC 300
– SINAMICS G120 inverters are available as PROFINET I/O device in the hardware
catalog.
A dialog box is displayed.
Operating Instructions, 07/2008 - FW 3.2, A5E00766042B AD
Control Units CU240S