Parameter index (IND) 2
The array subindex is in the PROFIdrive Profile referred to simply as "subindex".
Structure for acyclical communication
Figure 6-3
● The array subindex is an 8-bit value which is in acyclical data exchange mode transferred
● The parameter page selection task for additional parameters is performed in this case by
Structure for cyclical communication
Figure 6-4
● The array subindex is an 8-bit value which is in cyclical data exchange mode transferred
● The parameter page selection task for additional parameters is performed in this case by
Control Units CU240S
Operating Instructions, 07/2008 - FW 3.2, A5E00766042B AD
word
nd
IND structure acyclic
in the low-order byte (bits 0 to 7) of the parameter index (IND).
the high-order byte (bits 8 to 15) of the parameter index. This structure conforms to the
USS specification.
Example: Coding for parameter no. in PKE and IND for "P2016, Index 3".
IND structure cyclic
in the high-order byte (bits 8 to 15) of the parameter index (IND).
the low-order byte (bits 0 to 7) of the parameter index.
Communication
6.1 PROFIdrive Profile V4.1