Communication
6.2 Cyclic Communication
6.2.4

Switch over behavior of Communication telegram

Overview
When switching over the communication telegram, a number of paramaters values is
changed simultanously.
The following parameters might be concerned:
● P0820/P0821: Select Drive Data Set
● P1035: MOP up source
● P1036: MOP down source
For details refer to the following table
Notes to the tables:
● P0700 =1 => Commands via BOP
● P0700 = 2: => Commands via Terminals
● P0700 = 4: => Commands via USS on RS232
● P0700 = 6: => Commands via Fieldbus,
Table 6-10
Switch over behavior of telegram structures, Part 1
P0922 =
1 → 20
if P0700 =
1, 2
P0820 =
no change 2013.15
P0821 =
no change no change no change no change 2091.5
P1035 =
19.13
P1036 =
19.14
132
– PROFIBUS: P2090 (control word 1) and P2091 (control word 2)
– PROFInet: P8890 (control word 1) and P8891(control word 2)
4
6
2090.15
8890.15
19.13
19.13
19.14
19.14
1 → 350
if P0700 =
1, 2, 4
6
no change 2091.4
8891.4
8890.15
no change 2090.13
8890.13
no change 2090.14
8890.14
Operating Instructions, 07/2008 - FW 3.2, A5E00766042B AD
1 → 352/354
if P0700 =
1, 2, 4
6
no change no change no change no change
no change no change no change no change
no change 2090.13
8890.13
no change 2090.14
8890.14
1 → 999/353
if P0700 =
1, 2, 4
6
no change no change
no change no change
Control Units CU240S