Old Power
Power
Smart Sensor
State
Type
3. Select the
Refresh
button to (as required) to update the contents of the Smart RF screen and the
attributes of the devices within the selected RF Domain.
4. Select the
Interactive Calibration
within the selected RF Domain. The results of the calibration display within the Smart RF screen. Of
particular interest are the channel and power adjustments made by the Smart RF module. Expand the
screen to display the Event Monitor to track the progress of the Interactive Calibration.
5. Select
Calibration Result Actions
on the results of the Interactive Calibration. The results of an Interactive calibration are not applied to
radios directly, the administrator has the choice to select one of following options.
Replace
Write
Lists the transmit power assigned to each listed Access Point MAC
address within this RF Domain. The power level may have been increased
or decreased as part an Interactive Calibration process applied to this RF
Domain. Compare this Old Power level against the Power value to right of
it (in the table) to determine whether a new power level was warranted to
compensate for a coverage hole.
This column displays the transmit power level for the listed Access Point
MAC address after an Interactive Calibration resulted in an adjustment.
This is the new power level defined by Smart RF to compensate for a
coverage hole.
Defines whether a listed Access Point is smart sensor on behalf of the
other Access Point radios comprising the RF Domain.
Displays the current state of the Smart RF managed Access Point radio.
Possible states include: Normal, Offline and Sensor.
Displays the radio type (802.11an, 802.11bgn etc.) of each listed Access
Point radio within the selected RF Domain.
button to initiate a Smart RF calibration using the Access Points
to launch a sub screen used to determine the actions taken based
Figure 12-20 Save Calibration Result screen
Only overwrites the current channel and power values with the new
channel power values the Interactive Calibration has calculated.
Writes the new channel and power values to the radios under their
respective device configurations.