5 User Management
Step 6 (Optional) Run:
stopbits { 1.5 | 1 | 2 }
The stop bit is set.
By default, the stop bit is 1 bit.
Step 7 (Optional) Run:
databits { 5 | 6 | 7 | 8 }
The data bit is set.
By default, the data bit is 8.
----End
When the user logs in to a router through an AUX port, the configured attributes for the
console port on the super terminal should accord with the attributes of the port on the router.
Otherwise, the user cannot log in to the router.

5.3.3 Configuring AUX Terminal Attributes

Do as follows on the router:
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
user-interface aux 0
The AUX user interface view is displayed.
Step 3 Run:
shell
AUX terminal service is enabled.
Step 4 Run:
idle-timeout minutes [ seconds ]
User idle timeout is enabled.
By default, idle timeout period for users is 10 minutes.
Step 5 Run:
screen-length screen-length
The screen length of the terminal screen is set.
By default, the length of the terminal screen is 24 lines.
Step 6 Run:
history-command max-size size-value
5-12