Optional)Configuring Limits For Incoming Calls And Outgoing Calls; Configuring Vty Terminal Attributes - Huawei quidway s7700 Configuration Manual

Smart routing switch
Hide thumbs Also See for quidway s7700:
Table of Contents

Advertisement

Quidway S7700 Smart Routing Switch
Configuration Guide - Basic Configuration
If the maximum number of VTY user interfaces to be configured is larger than the maximum
number of current interfaces, the authentication mode and password need to be configured for
newly added user interfaces.
For newly added user interfaces, the system applies password authentication by default.
For example, a maximum of five users are allowed online. To allow 15 VTY users online at the
same time, you need to run the authentication-mode command and the set authentication
password command to configure authentication modes and passwords for user interfaces from
VTY 5 to VTY 14. The command is run as follows:
<Quidway> system-view
[Quidway] user-interface maximum-vty 15
[Quidway] user-interface vty 5 14
[Quidway-ui-vty5-14] authentication-mode password
[Quidway-ui-vty5-14] set authentication password cipher huawei
----End
5.4.3 (Optional)Configuring Limits for Incoming Calls and
Outgoing Calls
You can set the limit on incoming and outgoing calls for VTY user interfaces.
Context
Do as follows on the switch that the user logs in to:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
user-interface vty first-ui-number [ last-ui-number ]
The VTY user interface view is displayed.
Step 3 Run:
acl acl-number { inbound | outbound }
The limits to calling in/out of VTY are configured.
When you need to prevent a user of certain address or segment address from logging in to the
switch, use the inbound command; when you need to prevent a user who logs in to a switch
from accessing other switchs, use the outbound command.
----End

5.4.4 Configuring VTY Terminal Attributes

You can configure the timeout period for idle users, maximum number of lines to be displayed
on each screenor the maximum number of characters in each line, and the size of the historical
command buffer for a VTY interface.
Issue 01 (2011-07-15)
Huawei Proprietary and Confidential