Operation and Programming with Honeywell VCL Protocol
Program Preset
Recall Preset
Preset Tours
66
Up to 160 Presets can be defined. Presets are numbered 0–159. Presets 71–99 are
reserved for special ACUIX functions and cannot be programmed. Refer to
a list of Presets 71–99 and their functions.
For example, to program Preset 1 using the HJZTP controller:
1.
Move the selected dome to view the desired Preset position, using the joystick,
zoom, focus and iris keys.
2.
Press and hold Preset.
3.
Press 1.
4.
Release Preset. The current position of the dome has now been defined as Preset
1.
For example, to seek Preset 1 using an HJZTP controller:
1.
Press 1.
2.
Press Preset. The camera moves at the maximum speed to the previously defined
Preset 1.
The user may also select Presets 1–4 by single key presses using the keys labeled Preset
1 to 4.
Caution
Continuous Preset Tour operation for extended periods of time
(more than 8 hours) is not recommended. Continuous operation
results in increased zoom lens failure and maintenance expense.
Similarly, avoid setting auto focus to continuous.
Preset Tours function the same for VCL protocol as described in
in
Chapter 3, Operation and Programming with Honeywell Diamond
When using VCL protocol, Preset Tours must be programmed using the on-screen setup
menu. The on-screen setup menus are accessed by sending a Preset 90 command to the
ACUIX.
Table 4-2
for
Preset
Tours, page 43,
Protocol.