Switch Settings
Parity
Sample Switch Settings
Honeywell Diamond
24
DIP Switch SW6, positions 5 and 6 are used to set the parity.
Table 2-3
DIP Switch SW6 ACUIX Parity Settings
Parity
None
Even
Odd
Note
SW6, position 7 should be kept OFF. This switch is only used during
development for debugging purposes.
Legend for the following samples:
1 = On/ 0 = Off
For Honeywell Diamond protocol, the commonly used setting is 9600 baud, even parity.
SW5 - 10000001 (positions 1–8).
In above SW5–8 is ON to force reading from DIP switches. See
Override, page 26, for more information on setting SW5–8.
SW6 - 00101000 (positions 1–8) sets the ACUIX to 9600 baud with even parity.
Switch Position
5
6
OFF
OFF
ON
OFF
OFF
ON
DIP Switch Address