Table 7-17 Preset Tour Field Entries - Honeywell ACUIX User Manual

High speed dome camera
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

On-Screen Setup Menus
118
Table 7-17
Preset Tour Field Entries
Field
Usage
NUM (number)
Using the joystick, move the cursor to the desired field and
press Iris Open to activate. Use the joystick up and down
functions to change the value. If the field is more than one
digit, each digit can be changed individually by placing the
cursor on the digit and using the joystick up or down function.
PRESET
Selectable from 0 to 70, 74, and 100 to 160. Presets 71–73,
and 75–99 are reserved for special functions and cannot be
entered in a Preset Tour. When the field has the desired
number, press Iris Open to select the number. Iris Open also
moves the cursor to the next field.
VELOCITY
The Velocity field is the pan and tilt speed for the scan to go to
the Preset entered (1 to 480°/second). The default setting is
480°/second.
DWELL
The Dwell time is how long the ACUIX waits before it goes to
the next Preset in the list (0 to 99 seconds).
Note
4.
Inserting Presets: To insert a Preset between Presets, position the cursor on the
second Preset and press Focus Near to insert a line.
5.
Deleting Presets: To delete a Preset, place the cursor on the Preset line and press
Focus Far. The entire Preset line is deleted.
When you are finished entering Presets, press Iris Close. The cursor moves to S =
6.
Save.
7.
Press Iris Open to save the Preset Tour. To exit without saving, move the joystick
left to move the cursor to E = Exit and press Iris Open.
To delete a Preset Tour, move the joystick left to move the cursor to D = Delete,
8.
and then press Iris Open.
Privacy Zone Options (All Protocols)
Select 3 from the Function Programming
menu to access the Privacy Zone Options
menu. If the ACUIX is set for Diamond or
IntelliBus protocol, a password must be
entered. If the ACUIX is set for VCL, Pelco
P, or Pelco D protocols, the Privacy Zone
Options menu displays.
1.
Enter the Privacy Zone password. The
default password is blank. If the
ACUIX is set for VCL, or Pelco P/D
protocols, this step is skipped.
It is not recommended to select no delay (0 seconds).