Reset ACUIX

Manual Control

30
If the ACUIX is set to find home on startup, the message Finding Home... displays on
the monitor. Once the ACUIX has found home, the message Home Found... is briefly
displayed.
If the ACUIX is not set to find home on startup, the ACUIX finds home when it receives the
first control command. After the ACUIX finds home, the operator can control the ACUIX.
To reset an ACUIX using an HEGS5000/5001 controller you must be logged in as a Master
user on the controller. This reset is the same as if power was removed from the ACUIX and
then restored.
Press Dome Menu. Dome Setup Menu displays in the controller's LCD window. If
1.
Dome Setup Menu is not displayed, press + or - until it displays.
2.
Press Enter to access the Dome Setup Menu.
3.
Press 4 for Diagnostic Options.
4.
Press 7 for Scan and Camera Reset.
You can also press Clear/Manual on the HEGS5000/5001 controller four times to reset the
ACUIX.
Note
To restore the ACUIX to factory default settings, you can access the
on-screen setup menus or make use of the DIP switches as described in
Restore Factory Defaults
Manual control of an ACUIX dome includes pan, tilt, zoom, focus, and iris. To manually
control an ACUIX, the address of the ACUIX must be selected as the control camera. When
an operator performs a command at the controller, the controller sends out the control
command with the control camera address.
Example:
The operator has camera 2 selected as the control camera on the controller. The
operator performs the tilt function on the controller. The controller sends out the tilt
command to camera address 2. All the ACUIX domes on the control loop receive the
command, but only the ACUIX with address 2 performs the tilt command. If the ACUIX is
set to address 0, CAM-0000, the ACUIX responds to commands for all addresses.
When the ACUIX is being manually controlled the letter
M (manual) is added to the camera ID. The camera
message must be turned on in the Display Options
menu for it to be added to the video signal and viewed
on a monitor.