nStor Corporation Ultra S2S User Manual page 98

Raid controller with administor pc utilities
Table of Contents

Advertisement

Administering the Array
3
4
88
Manual Configuration
Choose the RAID Level you want to use for this system drive and press
<Enter>. The table shows the supported RAID levels.
AdminiStor PC Utilities
2 Channel - 16 Targ, 16MB SX DAC960SX at p1 0000 c0
<F1>= help
Disk Packs
A: 5dv
43385 MB
System Drives
#
Size (MB)
Raid
0
34708
5
Use Cursor keys for selection, <Enter> to select, <Esc> to Previous Menu
Field Name
RAID 0
RAID 1
RAID 3
RAID 5
RAID 6
RAID 7
The software will prompt you for the size (in megabytes) for the system
drive's space. It will automatically display the maximum size for the selected
RAID level. Enter the size you want and press <Enter>.
Based on the number of megabytes you enter, the software assigns the
necessary number of packs to this system drive. That is, if you enter a size
smaller than the size of the next available pack, the program will assign the
pack to the system drive. If the next size you enter for another system drive
still falls on the same pack, the next system drive will be assigned to the same
pack.
Cache
Pack
State
Thru
A...
Onln
RAID Level
0
1
3
5
0+1
JBOD
Version 7.11
Firmware: t6, v3.33-00
System Drive Definition
Create System Drive
Change Write Policy
LUN Mapping
RAID Level
RAID 0
43385 MB
RAID 1
21692 MB
RAID 3
34708 MB
RAID 5
34708 MB
RAID 6
21692 MB
RAID 7
43385 MB
Number of Drives
2 to 8
2
3 to 8
3 to 8
3 to 8
1

Advertisement

Table of Contents
loading

Table of Contents