nStor Corporation Ultra S2S User Manual page 58

Raid controller with administor pc utilities
Table of Contents

Advertisement

Configuration
11 Press <Esc> to return to the previous menu.
12 (Optional for Dual Active Configurations) Use the arrow keys to select
48
Configuring the Array
The Vendor Unique TUR is not used by this controller.
When "Disable CC for Invalid LUN" is disabled, the controller will
return a check condition for any command to an invalid LUN, including
the INQUIRY command. This a non SCSI-2 compliant. When "Disable
CC for Invalid LUN" is enabled, the controller will respond to an
INQUIRY command for an invalid LUN by setting the peripheral
qualifier field to 1 (device supported, not connected) which is SCSI-2
compliant. The default and recommended setting is Disabled.
With this parameter "enabled", the controller will respond with BUSY
status instead of QUEUE FULL status. The default setting is
"Disabled", but the correct setting depends on the host driver.
The Smart Large Transfer feature is not used with this controller.
Active - Active Parameters and press <Enter>.
AdminiStor PC Utilities
2 Channel - 16 Targ, 16MB SX DAC960SX at p1 0000 c0
<F1>= help
Item Help
This option turns off write caching during degraded mode. It has no effect
during normal or optimal conditions.
Use Cursor keys for selection, <Enter> to select, <Esc> to Previous Menu
Set the Conservative Cache parameter to "Disabled."
a
b
Set the Auto Failback parameter to "Disabled." The option is not
implemented for the CR8e subsystem.
Active - Active Parameters
Conservative Cache
Auto Failback
Force Simplex
Host Bus Reset Delay
Ctrlr Pres/Flt Signals
Ctrlr Pres/Flt Select
Simplex no RSTCOM
Version 7.11
Firmware: t6, v3.33-00
Disabled
Disabled
Disabled
0
Disbled
A
Disabled

Advertisement

Table of Contents
loading

Table of Contents