Change Disk State - nStor Corporation Ultra S2S User Manual

Raid controller with administor pc utilities
Table of Contents

Advertisement

Maintenance
3
4

Change Disk State

Change Disk State allows you to change the state of one or more disks. To change
a disk state:
1
2
3
4
104
Change Disk State
Miscellaneous errors – all other errors:
- Device times out on a command issued to it by the controller
- Active device was busy when the controller attempted to send it a
command
Error counters have the following properties:
A maximum of 127 errors can be recorded for each device in each table
Error counters can be reset to 0 by power-cycling the controller
Press any key to hide the error counts information.
Select another target drive, or press <Esc> to return to the Tools menu.
Select Change Disk State from the Tools menu. The software displays the
Change Disk Drive State screen.
Select the disk you wish to change.
The software displays the New State window, which shows the disk states.
Only the highlighted options are allowed for the currently selected drive. Disk
states (device statuses) are listed below:
DEAD
OFFLINE
REBULD
ONLINE
STANDBY
Select the state to which you want to change the highlighted disk to and left
click again or press <Enter>.
The software changes the state of the currently selected disk. When the
change is complete, the description of the drive's state in the physical drives
window will show the new state.
Repeat steps 2 and 3 for each disk you want to change.

Advertisement

Table of Contents
loading

Table of Contents