If you enter a number greater than the size of the next available pack, the
software assigns the next two packs to the system drive, and so on. If you
want to span a system drive across two or more packs, the packs must be all
identical in size and number of disks.
After defining the system drive, the software displays a summary of your
5
selections in the SysDrv Info window. It will prompt you to "Create System
Drive." Select YES to proceed and NO to start again.
6
If required, create additional System Drives repeating the preceding steps 1
through 5.
(Optional) Change the write policy. Select Change Write Policy from the
7
System Drive Definition menu. The cursor highlights the first system drive in
the System Drives window.
AdminiStor PC Utilities
2 Channel - 16 Targ, 16MB SX DAC960SX at p1 0000 c0
<F1>= help
Disk Packs
A: 5dv
43385 MB
System Drives
#
Size (MB)
0
34708
Use Cursor keys for selection, <Enter> to select, <Esc> to Previous Menu
8
Select the system drive you want to change and press <Enter>. This will
toggle the choices from "BACK" (write back) and THRU (write through).
9
Press <Esc> to exit the System Drives window.