NOTE:
If you are operating in a duplex environment, you must perform a rebuild
using Controller C-0.
To rebuild a physical drive:
1
Select Rebuild Redundancy from the Administration menu. If there is a drive
that requires rebuilding, AdminiStor PC Utilities (RAIDfx) displays the
rebuild screen.
AdminiStor PC Utilities
2 Channel - 16 Targ, 16MB SX DAC960SX at p1 0000 c0
<F1>= help
Item Help
Choose this option to rebuild a replaced physical drive.
Use Cursor keys for selection, <Enter> to select, <Esc> to Previous Menu
Select the drive to be rebuilt. The drive to be rebuilt will be indicated by the
2
letters DED (for "Dead drive") or REB.
3
Press <Enter> to initiate the rebuild.
The software rebuilds the drive, displaying its progress on the screen. If the
drive contains more than one system drive, the system drives are rebuilt
sequentially, beginning with the system drive with the lowest numerical
value.
4
When the Rebuild is complete, the software displays a message. Press any key
to return to the Administration menu.
Administration Menu
Rebuild Redundancy
Initialize System Drives
Check Consistency
Relinquish Partner
Kill Partner
Reset Controllers
Administering the Array
Version 7.11
Firmware: t6, v3.33-00
Rebuilding Drives