(Master subsystems only) Install the Ultra S2S RAID Controller(s).
6
a
Open the front door to the subsystem. Locate the controller in the
accessory kit and using precaution, handle the controller by its edges
and/or the latch clip.
b
Open the latching clip and carefully align the controller card edges into
the rails of the upper (left) bay.
c
Using both thumbs on the card's front edge, press firmly to fully seat the
controller. As the controller seats the latching clip will self secure.
d
Verify that the card is seated and the latch clip is secure. (In the following
illustration the rack-mount subsystem is used to illustrate the process.)
Latch Clip
Ultra S2S RAID Controller
in the upper (left) bay
SAF-TE Card
in the lower (right) bay
7
(Slave subsystems only) From the rear of the subsystem, remove the I/O
Interface card in the top (right) feature card slot, and install an Ultra
Extender Feature card.
Refer to the Feature Card User's Guide for more information. Repeat this step
for each slave subsystem in the configuration.
8
(VT100 Terminal use only) Connect the S2S Serial Communication cable to
the S2S Feature card at the Serial A connector using the RJ45 connector plug.
Connect the other end (DB9) to a VT100 terminal (or equivalent).
9
(Dual-Active configuration only) Connect one end of the S2S Cluster cable to
the S2S Feature card at the Serial B connector on the first Master subsystem
using the RJ11 connector plug. Connect the other end to the second Master
subsystem S2S Feature card to the Serial B connector.
10 Connect the data cables. Refer to the Cabling Configuration section on the
following page to determine the required cables for your configuration.
Installation
21