Duplex (Dual-Active) Configuration
Connect one end of the S2S Cluster cable to the S2S Feature card at the Serial
B connector on the "Master" subsystem using the RJ11 connector plug.
Connect the other end to the "Slave" subsystem S2S Feature card to the Serial
B connector.
Turn on the power to the CR8e's. After the power-on self-test has
successfully completed, the Status and Channel Mode LEDs will be solid
green.
Set the SCSI IDs. The IDs are configured via the Operator Control Panel
using the predefined sets. Access the Options menu and select "SAFTE
CHAIN ID" then choose "Master" for the subsystem identified as the master
subsystem and "Slave" for the subsystem identified as the slave subsystem.
After setting the subsystem identification you must power cycle the
subsystems. Observe normal power cycling precautions by waiting a
minimum of five (5) seconds before applying power again.
Proceed with completing the installation by configuring the array, refer to
Chapter 3 Configuration.