Section 5 Configuration File Programming
RINGBACK_TONE_GAIN
Value Format
Description
Value Range
Default Value
RINGBACK_TONE_TIMING
Value Format
Description
Value Range
Default Value
Web User Interface Reference
HOLD_ALARM_FRQ
Value Format
Description
Value Range
Default Value
HOLD_ALARM_GAIN
Value Format
Description
Value Range
Default Value
HOLD_ALARM_TIMING
Value Format
Description
170
Administrator Guide
Integer
Specifies the gain, in decibels, of the ringback tone.
-24–6
0
Comma-separated Integer
Specifies the pattern, in milliseconds, of ringback tones using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
0–16000 (0: Infinite time)
60,2000,3940
Tone Timings (Page 119)
Comma-separated Integer
Specifies the dual-tone frequencies, in hertz, of the hold alarm using 2
whole numbers separated by a comma.
0, 200–2000 (0: No tone)
425
Integer
Specifies the gain, in decibels, of the hold alarm.
-24–6
0
Comma-separated Integer
Specifies the pattern, in milliseconds, of the hold alarm using up to 10
whole numbers (on 1, off 1, on 2, off 2...) separated by commas.
Document Version 2012-07