Mazda RX-8 Workshop Manual page 1111

2011 - rx-8
Hide thumbs Also See for RX-8:
Table of Contents

Advertisement

2. When the generator itself or the ambient temperature are too high, the specified current
also cannot be verified. In this case, cool down the generator and recheck.
10. Turn the electrical loads (headlights, blower motor, rear window defroster, brake lights, etc.) on and
verify that the current reading increases more than the minimum value indicated below.
1. If it is not as specified, go to the PCM and generator shearing inspection. (See
generator shearing
NOTE:
Current required for generating power varies with the electrical loads applied.
Generator generated current (reference value) [Conditions] Ambient temperature: 20 °C {68 °F},
Voltage: 13—15 V, Engine hot
Engine speed (rpm) Terminal B current (Lower limit of current must be more than 0 A.)
1,000
2,000
PCM and generator shearing inspection
1. Connect the M-MDS to the DLC-2.
2. Inspect as follows:
Step
1 Measure the generator terminal B voltage when the electrical loads
on and off.
inspection.)
0—80 A
0—112 A
Inspection
PCM and
15 V
Go to Step 2.
*1
are
or
more
13—
*2
Normal
15 V
Action