Macro Function Commands - Ithaca PcOS Series 80PLUS Programmer's Manual

Ithaca pcos series 80plus pos thermal printer
Table of Contents

Advertisement

Epson Commands
Command Descriptions
Function
ASCII
Hexadecimal
Decimal
Range
Description
Function
ASCII
Hexadecimal
Decimal
Range
Description

Macro Function Commands

Function
ASCII
Hexadecimal
Decimal
Description:
Page 100
PcOS Series 80PLUS
Select printing position of HRI characters
GS
H
1DH
48H
<29>
<72>
0 ≤ n ≤ 3, 48 ≤ n ≤ 51
This command selects the printing position of HRI (Human Readable
Interpretation) characters when printing a bar code. n selects the printing
position as follows.
n
Printing position
0, 48
Not printed
1, 49
Above bar code
2, 50
Below bar code
3, 51
Both above and below the bar code
Select font for HRI characters
GS
f
1DH
66H
<29>
<102>
n = 0, 1, 48, 49
This command selects a font for the HRI (Human Readable Interpretation)
characters used when printing a bar code. n selects a font from the following
table.
n
Font
Font A (13 × 24)
0, 48
Font B (10 × 24)
1, 49
Start/end macro definition
GS
:
1DH
3AH
<29>
<58>
This command starts or ends macro definition. Macro definition starts
when this command is received during normal operation and ends when it
is received during the macro definition. The macro definition can contain
up to 2048 bytes. If the definition exceeds this value, the excess data is not
stored.
Rev B 4/13/99
Programmer's Guide
n
n
n
n
n
n
[EA]
[E]
[E]

Advertisement

Table of Contents
loading

Table of Contents