Miscellaneous Commands - Ithaca PcOS Series 80PLUS Programmer's Manual

Ithaca pcos series 80plus pos thermal printer
Table of Contents

Advertisement

Programmer's Guide
Function
ASCII
Hexadecimal
Decimal
Description
milliseconds.

Miscellaneous Commands

Function
ASCII
Hexadecimal
Decimal
Range
Default
[Epson TM-T8x]
[Axiohm 7193]
Description
Function
ASCII
Hexadecimal
Decimal
Description
Function
ASCII
Hexadecimal
Decimal
Usage
Description
PcOS Series 80PLUS
Sound buzzer
ESC
BEL
1BH
07H
<27>
<07>
This command sounds the internal buzzer, if equipped, for 550
Set horizontal and vertical motion units
GS
P
1DH
50H
<29>
<80>
0 ≤ x ≤ 255
0 ≤ y ≤ 255
x = 180, y = 360
x = 152, y = 152
This command sets the horizontal and vertical motion units to 1/x inches
and 1/y inches, respectively. When x and y are set to 0, the default setting
of each value is used.
Initialize printer
ESC
@
1BH
40H
<27>
<64>
This command clears the data in the print buffer and resets the printer to
the mode that was in effect when the power was turned on.
Clear printer
DLE
10H
<16>
Axiohm 7193 emulation mode only.
This command clears the print line buffer without printing and sets the
printer to the following conditions. Double-wide (12 dec) command is
canceled. Line spacing, pitch, and user-defined character sets and bit-
images in RAM are unaffected. Single-wide, single-high, nonrotated, and
left-aligned characters are set. The printer is restarted, and error status is
cleared in a fault condition. This command also returns paper exhaust to
the paper status if an alternate status has been requested using the ESC u
command (parallel interface only).
Rev B 4/13/99
Epson Commands
Command Descriptions
x
y
x
y
x
y
[EA]
[E]
[EA]
[A*]
Page 103

Advertisement

Table of Contents
loading

Table of Contents