Programmer's Guide
Function
ASCII
Hexadecimal
Decimal
Description
milliseconds.
Miscellaneous Commands
Function
ASCII
Hexadecimal
Decimal
Range
Default
[Epson TM-T8x]
[Axiohm 7193]
Description
Function
ASCII
Hexadecimal
Decimal
Description
Function
ASCII
Hexadecimal
Decimal
Usage
Description
PcOS Series 80PLUS
Sound buzzer
ESC
BEL
1BH
07H
<27>
<07>
This command sounds the internal buzzer, if equipped, for 550
Set horizontal and vertical motion units
GS
P
1DH
50H
<29>
<80>
0 ≤ x ≤ 255
0 ≤ y ≤ 255
x = 180, y = 360
x = 152, y = 152
This command sets the horizontal and vertical motion units to 1/x inches
and 1/y inches, respectively. When x and y are set to 0, the default setting
of each value is used.
Initialize printer
ESC
@
1BH
40H
<27>
<64>
This command clears the data in the print buffer and resets the printer to
the mode that was in effect when the power was turned on.
Clear printer
DLE
10H
<16>
Axiohm 7193 emulation mode only.
This command clears the print line buffer without printing and sets the
printer to the following conditions. Double-wide (12 dec) command is
canceled. Line spacing, pitch, and user-defined character sets and bit-
images in RAM are unaffected. Single-wide, single-high, nonrotated, and
left-aligned characters are set. The printer is restarted, and error status is
cleared in a fault condition. This command also returns paper exhaust to
the paper status if an alternate status has been requested using the ESC u
command (parallel interface only).
Rev B 4/13/99
Epson Commands
Command Descriptions
x
y
x
y
x
y
[EA]
[E]
[EA]
[A*]
Page 103