10/100BaseT
LAN connections
Printer Port
DIP Switches
DIP Switch Set-
ting
Restore Default IP Address and Clear Password
If the UniGateway EH-2101W's IP Address or password is lost, the following procedure can
be used to recover from this situation.
1. Turn the power to the UniGateway EH-2101W OFF.
2. Set DIP switch 1 ON.
3. Turn the power to the UniGateway EH-2101W ON.
4. Operate DIP switch 1 in the following sequence (you have 15 seconds to complete the
sequence):
•
OFF
•
ON
•
OFF
5. The UniGateway EH-2101W will now reset, and the Red Status LED flash. The following
changes will have been made. (Other configuration data is unchanged.)
•
IP Address set to its default value of 192.168.0.1
•
Network Mask set to 255.255.255.0
•
DHCP Server is enabled, and will allocate IP Addresses in the range 192.168.0.2 to
192.168.0.51.
•
The password cleared (no password).
6. You can now connect to the UniGateway EH-2101W and make any configuration changes
required
Use standard LAN cables (RJ45 connectors) to connect your PCs to
these ports.
The "Uplink" port can be used to connect to a standard port on
another Hub, using a standard LAN cable.
Use EITHER "Port 1" OR the "Uplink" port.
You can NOT use both.
Standard parallel printer port. If you wish to share a printer, connect
it here.
Description
1=off
Normal Operation.
2=off
1=off
DHCP Server function disabled.
2=on
1=on
Used to restore Default IP Address
2=off
and clear Password (See below).
1=on
Normal Operation.
2=on
Introduction
7