Advantech ADAM-4570 User Manual

Advantech ADAM-4570 User Manual

1/2/4 port ethernet to rs-232/422/485 data gateway
Hide thumbs Also See for ADAM-4570:
Table of Contents

Advertisement

ADAM-4570/4570L/4570S/
ADAM-4571/4571L/4571S/
EDG-4504
1/2/4 Port Ethernet to
RS-232/422/485 Data Gateway
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Advantech ADAM-4570

  • Page 1 ADAM-4570/4570L/4570S/ ADAM-4571/4571L/4571S/ EDG-4504 1/2/4 Port Ethernet to RS-232/422/485 Data Gateway User’s Manual...
  • Page 2 Copyright Notice This document is copyrighted, 2001, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd., reserves the right to make improve- ments to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd.
  • Page 3: Technical Support

    Advantech Customer Services Each and every Advantech product is built to the most exacting specifications to ensure reliable performance in the unusual and demanding conditions typical of industrial environments. Whether your new Advantech equipment is destined for the laboratory or the...
  • Page 4: Product Warranty

    Because of Advantech’s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product ever does prove defective, it will be repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you will be billed according to the cost of replacement materi- als, service time and freight.
  • Page 5 product returned without dated proof of purchase is not eligible for warranty service. 5. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer.
  • Page 6: Table Of Contents

    1.2 Features ................3 1.3 Specifications ..............4 1.4 Package Checklist ............6 Chapter 2: Getting Started ......7 2.1 Understanding the Advantech EDG Series ....9 2.1.1 Network Architecture ............9 2.1.2 Secure Communication ..........11 2.1.2.1 Data Integrity ............11 2.1.2.2 Access Control and Local Password Configuration12...
  • Page 7 Chapter 3: Installation and Configuration .. 29 3.1 Driver and Utility Installation ........30 3.2 Configuring the EDG Series — The Configuration Utility ..........31 3.2.1 Search for Specific EDG Series ........32 3.2.2 System Configuration ............. 34 3.2.3 Network Configuration ............ 37 3.2.4 Port Configuration ............
  • Page 8 Figure 2-16 Din Rail Mounting ..............23 Figure 2-17 Panel Mounting ................ 23 Figure 2-18 Connecting EDG Series series to the hub ......24 Figure 2-19 Power Connection for ADAM-4570/4570L/4570S/4571/ 4571L/4571S ................25 Figure 2-20 Power Connection for EDG-4504 ..........25 Figure 2-21 Serial Connection for ADAM-4570/4570L/4570S/4571/ 4571L/4571S.
  • Page 9 Figure 3-7 Port Configuration Window ............. 38 Figure 3-8 Security configuration ............. 40 Figure 3-9 Status messages ..............41 Figure 3-10 Unused ports ................43 Figure 3-11 Assign COM port to EDG Series ..........44 Figure 3-12 Warning window ..............44 Figure 3-13 Test window ................
  • Page 10 Tables Table 2-1 ADAM-4570/4570L/4570S LED Definition ....... 13 Table 2-2 ADAM-4571/4571L/4571S LED Definition ....... 15 Table 2-3 EDG-4504 LED Definition ............17...
  • Page 11: Chapter 1: Overview

    Overview...
  • Page 12: Introduction

    1.1 Introduction The Advantech Ethernet Data Gateway series (EDG series) is a lightening fast and cost effective data gateway between RS-232/ 422/485 and Ethernet interfaces. This unit immediately upgrades your existing device for integration into the Internet world. The ADAM-4570/ADAM-4571/EDG-4504 provides multiple RS- 232/422/485 serial ports easily individually configured for your needs and ADAM-4570L/4571L provides RS-232 serial ports.
  • Page 13: Features

    In addition, The EDG series comes with a Windows-based con- figuration and port-mapping utility. The configuration tool can auto-detect all EDG series on the local network. It also lets you adjust all settings easily. The port mapping utility helps you to set up 255 ports for one Windows 95/98/NT/2000/ME/XP plat- form.
  • Page 14: Specifications

    Network: 10/100 BASE-T standard Serial: ADAM-4570/ADAM-4571/EDG-4504: RS-232, RS-422 and RS-485; ADAM-4570L/4571L: RS-232; ADAM-4570S/4571S: RS-422 and RS-485 • Port: 1/2/4 independent RS-232/422/485 ports ADAM-4570: Two RS-232/422/485 ports ADAM-4570L: Two RS-232 ports ADAM-4570S: Two RS-422/485 ports ADAM-4571: One RS-232/422/485 port ADAM-4571L: One RS-232 port...
  • Page 15 Easy-to-manage port mapping utility • Driver Supported: Windows 95/98/NT/2000/ME/XP driver • Power Requirements: unregulated 10 to 30 Vdc with surge protection • Power Consumption: ADAM-4570: 4W ADAM-4571: 3.5W ADAM-4570L/4571L: 1.5W EDG-4504: 4.5W • Placement: DIN-rail, panel mounting, piggyback stack (ADAM-4570/4570L/4570S/4571/4571L/4571S) DIN-rail, panel mounting (EDG-4504) •...
  • Page 16: Package Checklist

    • User’s Manual • CD-ROM for utility and manual • 1/2/4 RJ-48 to DB-9 serial cables (except ADAM-4571L) • One RS-232 loopback DB-9 tester • Five stickers • NYLON DIN-rail Mounting Adapter • SECC Panel Mounting Bracket Advantech EDG series User’s Manual...
  • Page 17: Chapter 2: Getting Started

    Getting Started...
  • Page 18: Figure2-1 Installation Flow Chart

    EDG series comes ready for all network connec- tions, including Ethernet, and RS-232/422/485 port connections. We begin this chapter with a brief showing the installation procedure. You can take flow chart for reference. Figure2-1 Installation Flow Chart Advantech EDG series User’s Manual...
  • Page 19: Understanding The Advantech Edg Series

    2.1 Understanding the Advantech EDG Series The EDG series is an advanced data gateway unit. It extends traditional COM ports of a PC with access over a TCP/IP net- work. Through networking, you can control and monitor re- mote serial devices either over a LAN or over the WAN.
  • Page 20: Figure 2-2 Network Architecture (1)

    The following illustration shows the network architecture as be- low: Eth ernet ADAM RS-23 2/4 22/4 85 Port 1 Port 2 +Vs GND Figure 2-2 Network Architecture(1) Figure 2-3 Network Architecture(2) Advantech EDG series User’s Manual...
  • Page 21: Secure Communication

    2.1.2 Secure Communication Advanced multiple security features protect the system and make data more private and secure. The ADAM-4570S/4571S guards your network and data by multiple security protections: T-DES (Triple Data Encryption Standard, which is specified in FIPS PUB 46-2 and American National Standard X9.25) strong en- cryption, PKCS#5 (Password-based Cryptographic Standard #5), and IP address authorization.
  • Page 22: Access Control And Local Password Configuration12

    ADAM-4570S/4571S protects all configuration settings from being changed inadvertently. When this option is enabled, only the corresponding PC can configure the module. The multiple security mechanisms work to prevent unauthorized access to your RS-422/485 networks. Advantech EDG series User’s Manual...
  • Page 23: Top / Front / Rear View

    2.1.3 Top / Front / Rear View 2.1.3.1 ADAM-4570/4570L/4570S There are five network status LEDs located on the top panel of ADAM-4570/4570L/4570S, each with its own specific func- tion. Color Status Description Heartbeat (1 time/sec) Not working Status/Power Power ON...
  • Page 24: Figure 2-4 Adam-4570/4570L/4570S-Top Panel

    Figure 2-4 ADAM-4570/4570L/4570S—Top Panel Figure 2-5 ADAM-4570/4570L/4570S—Front Panel Figure 2-6 ADAM-4570/4570L/4570S—Back Panel Advantech EDG series User’s Manual...
  • Page 25: Adam-4571/4571L/4571S

    2.1.3.2 ADAM-4571/4571L/4571S There are four LEDs located on the top panel of ADAM-4571/ 4571L/4571S, each with its own specific function. Color Status Description Heartbeat (1 time/sec) Not working Status/Power Power ON Green Power OFF 100 Mbps speed 10 Mbps speed Speed/Link Valid network link Green...
  • Page 26: Figure 2-7 Adam-4571/4571L/4571S-Top Panel

    Figure 2-7 ADAM-4571/4571L/4571S—Top Panel P o rt1 Figure 2-8 ADAM-4571/4571L/4571S—Front Panel Figure 2-9 ADAM-4571/4571L/4571S—Back Panel Advantech EDG series User’s Manual...
  • Page 27: Edg-4504

    2.1.3.3 EDG-4504 There are 13 LEDs located on the top panel of EDG-4504, each with its own specific function. Status Description Heart beat (1 time/sec) Status Not working 10 Mbps speed Invalid 10 Mbps Network link 100 Mbps speed 100M Invalid 100 Mbps Network link Ethernet data being received TX (Ethernet)
  • Page 28: Figure 2-10 Edg-4504-Top Panel

    Figure 2-10 EDG-4504—Top Panel Figure 2-11 EDG-4504—Front Panel Figure 2-12 EDG-4504—Front Panel Advantech EDG series User’s Manual...
  • Page 29: Stickers

    2.1.4 Stickers If you forgot the IP addresses of specific EDG Series or where the host PC is mapped to the ADAM-4570 port, we have pro- vided five stickers for you to note the IP addresses and place in a secure location. For example, 172.20.20.5: The IP address of specific ADAM-4570...
  • Page 30: Figure 2-13 Panel Mounting

    Panel Mounting The ADAM-4570/4570L/4570S/4571/4571L/4571S can be attached to a wall using the included metal brackets. Each bracket comes with four screws; first attach the brackets to the bottom of the ADAM-4570/4570L/4570S/4571/4571L/4571S. Next, screw each bracket to a wall. Figure 2-13 Panel Mounting...
  • Page 31: Figure 2-14 Din Rail Mounting

    DIN Rail Mounting You can mount the ADAM-4570/4570L/4570S/4571/4571L/ 4571S on a standard DIN Rail. First, using two screws, attach the metal plate to the DIN Rail bracket. Because the screw heads are beveled, the tops of the screws will be flush with the metal plate.
  • Page 32: Figure2-15 Piggyback Stack

    Piggyback Stack ADAM-4570/4570L/4570S/4571/4571L/4571S can be stacked as seen in the figure below. Figure2-15 Piggyback Stack Advantech EDG series User’s Manual...
  • Page 33: Edg-4504

    2.2.1.2 EDG-4504 Figure 2-16 Din Rail Mounting Figure 2-17 Panel Mounting Chapter 2 Getting Started...
  • Page 34: Network Connection

    EDG Series is up to 100 meters (ca. 300 ft). 2.2.3 Power Connection You should take the following steps to connect EDG Series power. Figure 2-18 Connecting EDG Series series to the hub Advantech EDG series User’s Manual...
  • Page 35: Figure 2-19 Power Connection For Adam-4570/4570L/4570S/4571/ 4571L/4571S

    1. Connect the power cable to 2-pin connector 2. Connect power cable to power adapter Figure 2-19 Power Connection for ADAM-4570/4570L/4570S/4571/4571L/ 4571S Figure 2-20 Power Connection for EDG-4504 If the EDG Series is working properly, the green power LED will light up , indicating that the EDG Series is receiving power.
  • Page 36: Serial Connection

    2. Refer to the following table for details on serial cable RJ-48 to DB-9 pinouts. Figure 2-21 Serial Connection for ADAM-4570/4570L/4570S/4571/4571L/ 4571S. Advantech EDG series User’s Manual...
  • Page 37 RJ-48 PIN Name RJ-48 DB-9 Chapter 2 Getting Started...
  • Page 38: Edg-4504

    2. The DB-9 pinouts is the same as ADAM-4570/4570L/4571 Figure 2-22 Serial Connection for EDG-4504 Advantech EDG series User’s Manual...
  • Page 39: Chapter 3: Installation And Configuration

    Installation and Configuration...
  • Page 40: Driver And Utility Installation

    IP protocol installed. Following are the installation instructions to set up the EDG Series. 1. Insert the Advantech industrial communication CD-ROM into the drive (e.g. D:\) on the host PC. Change the host comput- er’s default drive from C: to D: 2.
  • Page 41: Configuring The Edg Series - The Configuration Utility

    Figure 3-1 Configuration Utility 3.2 Configuring the EDG Series — The Configuration Utility The EDG Series provides easy Windows configuration through Ethernet connection. This Windows utility searches all the EDG Series and devices on the network automatically and you can configure various parameters for TCP/IP configuration easily.
  • Page 42: Search For Specific Edg Series

    EDG Series devices (see Figure 3-2) or select a group of ADAM-4570S/4571S (see Figure 3-3) or just select one ADAM-4570 (see Figure 3-4). When you select a specific de- vice, the LED that stands for “Status” will glow for 8 minutes.
  • Page 43: Figure 3-3 Locatet He Desired Group Of Adam-4570S/4571S

    3. The “Status” LED of all ADAM-4570S/4571S on the LAN will turn on 4. It’s the same way to locate one device. Figure 3-3 Locate the desired group of ADAM-4570S/4571S Figure 3-4 Locate specific ADAM-4570S/4571S Chapter 3: Installation and Configuration...
  • Page 44: System Configuration

    MAC Address. The MAC Address is what helps the local system to identify and locate each Ethernet data gate- way device. This MAC Address is already set before delivery from factory, hence no need for further configuration. Advantech EDG series User’s Manual...
  • Page 45: Firmware Version

    Device Name Configuration utility provides a default name for device to distin- guish a specific EDG Series from other EDG Series. You can update the default device name based on your application. Names longer than 128 characters cannot be used. It is best to choose a name you can remember.
  • Page 46 "NONE". The "Input Password" col- umn will be disable Type EDG Series offers three serial interfaces, RS-232, RS-485 and RS-422. You can use any one of these serial interfaces accord- ing to your requirements. Advantech EDG series User’s Manual...
  • Page 47: Network Configuration

    3.2.3 Network Configuration Figure 3-6 Network Configuration Window MAC Address This does not need configuration. Link Speed This function will show the current linking speed to be either 10Mbps or 100Mbps. However, the utility will auto-detect the current transmission speed on the network segment and set the transmission speed for the device accordingly without your fur- ther efforts.
  • Page 48: Port Configuration

    EDG Series with the individual IP ad- dress. Note: The EDG Series does not support auto IP address con- figured by DHCP server. 3.2.4 Port Configuration Figure 3-7 Port Configuration Window Advantech EDG series User’s Manual...
  • Page 49: Data Bits

    Name To specify which port on the EDG Series is to be connected to the serial device. Description You can give more detailed description of the function of the port for easy management and maintenance. Descriptions longer than 128 characters cannot be used. Type EDG Series offers three kinds of serial interfaces, RS-232, RS- 485 and RS-422.
  • Page 50: Security Configuration

    If this option is enabled, any PC can access data from this EDG Series. The specified IP which can access If you do not want many PCs to have the access right, you can limit at most 32 PCs to access data from this EDG Series. Advantech EDG series User’s Manual...
  • Page 51: Status Messages

    3.3 Status Messages The status message shown at the bottom of the utility window reflects the current status of EDG Series. Figure 3-9 Status messages “Read” The configuration utility has found the EDG Series and it is ready for use. “Searching EDG COMport”...
  • Page 52: Connection Diagnostic

    If the EDG Series cannot be pinged, you will need to ask someone at the remote site to check and see if the power is on, and make sure that the connection is okay. Advantech EDG series User’s Manual...
  • Page 53: Port Mapping Utility

    3.4 Port Mapping Utility The purpose of the port mapping utility is to help you manage all ports which are in one Windows 95/98/NT/2000/ME/XP plat- form. The utility displays three types of ports: Used ports, Un- used ports and EDG Series ports. Please follow the steps. 1.
  • Page 54: Figure 3-11 Assign Com Port To Edg Series

    Figure 3-11 Assign COM port to EDG Series Figure 3-12 Warning window 4. The port has been added into EDG Series 5. If you want to remove the COMport, click DELETE to re- move this. Advantech EDG series User’s Manual...
  • Page 55: Security Setting

    6. After you complete the configuration, click ”Apply”. 3.4.1 Security Setting When you select ADAM-4570S or ADAM-4571S in the col- umn "Model of Installed Device", the view of port mapping util- ity will change, as the figure shown below. As you may have observed, it is added with "Security" setting. Chapter 3: Installation and Configuration...
  • Page 56: Self Test Function

    (provided in the package). Refer to the following chart for the specifications of this loopback tester. The loopback test only applies to RS-232 mode. The test is divided into two parts: Signal test and Communication Parameters test. Advantech EDG series User’s Manual...
  • Page 57: Figure 3-13 Test Window

    1. Click the Test button in the Port Mapping utility. Figure 3-13 Test window Signal Test • RTS CTS: Check the RTS and CTS signals between two ports. • DTR RI: Check the DTR and RI signal between two ports. •...
  • Page 58: Upgrading Edg Series's Firmware Download

    Figure 3-14 Loopback test 3.4.3 Upgrading EDG Series’s Firmware Download Advantech continually upgrades its firmware to keep pace with the ever-expanding world of computing. You can use the Down- load function located on Port Mapping utility to carry out the upgrade procedure.
  • Page 59: Figure 3-15 Update Firmware Window

    1. Click on the toolbar Update FW icon. Figure 3-15 Update firmware window 2. Locate and then select the filename of the firmware that you downloaded. Figure 3-16 Select the file Chapter 3: Installation and Configuration...
  • Page 60: Figure 3-17 Download Firmware

    3. After downloading firmware completely, click on the Reboot button. The EDG Series will restart automati cally. Figure 3-17 Download firmware Note: After clicking Reboot button, configuration utility will not reboot EDG Series untill no application program access this EDG Series. Advantech EDG series User’s Manual...
  • Page 61: Save The Configuration

    3.4.4 Save The Configuration If you want to save or recover the configuration, you can select the “Import/Export” items. 1. a. Select “File” b. Select “Import” or “Export” 2. Save or open the configurations Chapter 3: Installation and Configuration...
  • Page 62: Auto-Reconnect Function

    NOT enable the “Host idle” function at the same time. The same also applies in reverse, e.g. if you want to enable the “Host idle” function, you also can NOT enable the “Auto-reconnect” function at the same time. Advantech EDG series User’s Manual...
  • Page 63: Chapter 4: Troubleshooting

    Troubleshooting...
  • Page 64 EDG Series. If you are still having problems after reading this chapter, contact your dealer, or e-mail Advantech for help. “Configuration Utility can not find EDG Series” 1. Check POWER LED. If it is off, you have to check : •...
  • Page 65 “Cannot change the IP address or other server proper- ties” The network administrator is the only one allowed to modify the EDG Series’s configuration. Keep in mind, even when mul- tiple hosts share the same network, administrative access is still protected.
  • Page 66 Advantech EDG series User’s Manual...

Table of Contents