Remote Control - Rinnai Advance Operation And Installation Manual

Flame fire
Table of Contents

Advertisement

ETR Operation
Lock
The 'Lock' function will help prevent accidental operation and small children from altering the
controls. To operate press the 'Lock' button. The function is activated immediately and the
'Lock' indicator will glow. To deactivate press the 'Lock' button for three seconds and the 'Lock'
indicator will go out.
during normal operation the 'Lock' may be activated and all the controls, other than the OFF switch, will be
locked. deactivating the 'Lock' releases the controls. If the 'Lock' is activated whilst the heater is turned off,
then all functions will be locked. If the heater is turned off while the 'Lock' is activated, it cannot be turned on
again until the 'Lock' is deactivated.
Flame
To operate press the 'Flame' button. This function will automatically override the thermostat
and set the heater to a default high heat setting for full visual flame effect.
Auto Off
The 'AUTO OFF' function is an energy saving feature designed to control the room temperature
economically. If the room temperature continues to rise when the heater is thermostatically
turned down to its lowest setting the front burner will turn off leaving only the pilot flame
operating. When the room temperature requires further heating the heater will automatically
re-ignite to warm the room. This feature also prevents overheating in small rooms.
Override
This function is intended to be used to manually override the current operation of the heater
when the heater is in 'Timer' mode.
For example: if the heater is in standby mode (i.e. between the finishing and starting timer of
a timer operation), and the 'Override' button is selected, then the heater will begin to operate
and heat the room.
To operate press the 'Override' button, the 'Override' indicator will flash. To manually
deactivate press the 'Override' button again. The 'Override' indicator will go out, and the
heater will return to standby mode.
The heater will continue to operate in 'Override' until the 'Override' button is pressed again, or one of the
timers takes over the operation of the appliance. This means that the 'Override' mode will automatically drop
out if a programmed starting time is reached. The appliance will then return to operating at times programmed
into the 'Timer(s)'.

Remote Control

The remote control will not turn heaters on if 'Timer(s)' have been set. To manually operate
when 'Timer(s)' are not selected, press the 'ON' or 'OFF' button. To alter the temperature
when the heater is operating, press the
Rinnai New Zealand
or
buttons.
10