Installation
Clearances
The appliance must not be installed where curtains or other combustible materials could come
into contact with it. In some cases, curtains may need restraining.
Mantles, Surrounds and Hearths
Mantles and surrounds can be added to compliment design providing they conform to the
clearances below.
Mantles
•
Minimum clearance of 200mm above the fire and a maximum of
150mm at this height
•
For additional overhang, 100mm of vertical clearance is required for
every 50mm of added depth, i.e. a 200mm mantle requires 300mm of
vertical clearance
Hearths
A hearth is not necessary but can be used for decorative purposes or
protection of sensitive flooring materials if required. If used the bottom
of the appliance must be level with the top of the hearth so there is a
continuous level.
Rinnai New Zealand
300mm
300mm
8
300mm
Reflection: 03-08