Electrical Connection - Rinnai Advance Operation And Installation Manual

Flame fire
Table of Contents

Advertisement

Installation Procedure
Preparation
Remove Glass
Place the appliance on a flat surface. Remove screws from the top and
lower glass retainers and lift off glass. This makes it easier to maneuver
Retainers
the fire into the cavity.
Remove Logset
Carefully remove from the heater and place in a safer location until
required.
Make sure that the gas flare fitting and gas supply pipe are clean and free
Check Flexi-Pipe
of damage and fit together ready for fitting.
Connection

Electrical Connection

This appliance has a power cord with a three pin plug supplied. The power cord passes through
the insulating bush in the lower right hand side of the rear panel and must be plugged into a
230-240V, 10A earthed power point.
The power point must not be above the unit. The electric isolation switch must be accessible
after the appliance has been installed.
If using a zero clearance box, there is a knock out for the electrical connection with an edge
protector supplied. This needs to be cut and fitted.
Advance Masonry
Electrical cord is not fire rated. do not thread out of the back of the fire as
Installations
there is a risk the cord could come into contact with the back of the heater.
In-Wall Control
Refer instructions on page 29.
Panel
Masonry Installations - Apply Sealing Strip
Apply sealing strip to rear of spacer/heater as shown. The strip is intended
to form a seal between the heater and the fireplace. If an adequate seal
cannot be formed with this strip another means of sealing must be used (non
combustible insulation) between the fireplace and the spacer/heater body.
Rinnai New Zealand
24
Electrical cable
Reflection: 03-08