Flame Fire ETR Electronic Timer and Remote Operating and Installation Instructions Freestanding Royale ETR (Australia) Timberflame FS35 ETR (New Zealand) Table of Contents Customer Instructions Control Panel Layout Operation Setting the Clock Operating the Timers Error Codes Safety Points Troubleshooting...
CONTROL PANEL LAYOUT TIME/TEMP. Display LOCK Button Shows either the time of day, Indicates lock temperatures or coded error function messages. CLOCK ADJUSTMENT AND TIMER INDICATORS Indicates that clock or dual timer programme is being set. Flame Function Med. High heat setting and overides thermostat TIMER Indicator TIME / TEMP.
OPERATION TO OPEN THE CONTROL PANEL • Lift lightly in the centre of the lid where there is a catch. The control panel lid will then open backward to an angle. TURNING ON • Press the ON/OFF button to operate the heater. The ON indicator will glow green. The spark generator will be heard before the burner ignites and the ON indicator glows red, indicating that the heater is alight.
OVERRIDE • This function is intended to be used to manually override the current operation of the heater. For example; If the heater is in standby mode (ie. between finishing time and starting time of a Timer), and the OVERRIDE button is selected, then the heater will begin to operate and heat the room. To operate the OVERRIDE simply press the OVERRIDE button.
SETTING THE CLOCK SETTING THE CLOCK • --:-- When the appliance is first plugged in or after a power failure, the Digital Display will show As an example, let’s set the clock to 10:35 am: Press the SET TIMES button once, the Clock indicator will flash. Press and hold the “...
SERVICE Rinnai has a service and spare parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs service, please ring one of the service contact numbers on page 14 of this booklet.
ERROR CODES ERROR CODE MESSAGE • The Flame Fire ETR has the ability to check its own operation continuously. If a fault occurs, an Error Message will flash on the Digital Display of the control panel. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call.
SAFETY POINTS Do not restrict the warm air discharge by This appliance must not be used for any placing articles in front of the heater. purpose other than heating. Do not spray aerosols whilst the heater is Young children should be supervised at all operating.
Ensure appliance fan switch is in ON position Small soot deposit Normal operation No action required Inadequate Flue System Severe soot deposit Call Rinnai Service Dept./Agent Log Misalignment forming on Glass or Incorrect Gas Pressure Logs Condensation on Glass Normal operation...
LOCATION When positioning the heater, the main points governing the location are: 1. Flueing. 2. Warm air distribution. 3. The heater must not be installed where curtains or other combustible materials could come into contact with it. In some cases, curtains may need restraining. See below for minimum clearances required.
FLUEING • This heater requires a minimum 3m. flue. • Position the heater. • Suspend a plumbline from the ceiling to the centre of the flue socket. • Mark the centre of the flue in the ceiling. • Make a small hole in the ceiling and double check that the flue system will be at least 25 mm clear of combustible materials.
LOG INSTALLATION he logset is packed inside the heater and the packaging must be removed prior to installing the logset in its correct position. • Open both side panels. • Remove fastenings on both sides of the top glass retainer. Lift retainer away from heater.
The guard on this appliance conforms to AGA. requirements. It is designed to prevent the risk of fire or injury from burns, and no part of it should be permanently removed. IT DOES NOT GIVE FULL PROTECTION TO YOUNG CHILDREN OR THE INFIRM. NOTE: RINNAI RESERVES THE RIGHT TO CHANGE OR MODIFY SPECIFICATIONS WITHOUT NOTICE.
Model: FGL35ETRBN (NG) Australia FGL35ETRBL (LP) Australia FS35ETRN (NG) New Zealand FS35ETRL (Propane) New Zealand Rinnai Inbuilt Radiant/Convector, glass-fronted, ceramic log space heater Description: with forced convection and natural draught flue system. Input: 35 MJ/h Natural Gas and Propane. Gas Control: Rinnai Electronic Control Valve.
INSTALLATION / COMMISSIONING CHECKLIST (To be completed by certified Gas Installer) ____________________ Model: 1. Was a fireplace inspection carried out? (ie. clearances, combustibles etc.) 2. Was chimney inspected? 3. Did chimney require flue liner system to be installed? If NO, did chimney meet specified criteria as per manual? 4.