Removing And Installing 4X3.5" Hotswap Hard Drive Cage Assembly; Removing 4X3.5" Hotswap Hard Drive Cage With Backplane; Figure 46. Securing The 2.5" Hdd On Fixed Hdd Carrier Tray; Figure 47. Inserting The Hdd Carrier Tray - Intel P4000M Service Manual

Server chassis family
Table of Contents

Advertisement

8.
Insert the HDD carrier tray into chassis.
9.
Connect power and data cables on HDD.
10. Install the Fixed HDD EMI shield. For instructions, see "Installing the Fixed HDD EMI Shield".
11. Install the front bezel. For instructions, see "Installing the Front Bezel".
12. Install the air duct if the air duct is removed. For instructions, see "Installing the Airduct"
13. Install the chassis cover. For instructions, see "Installing the Chassis Cover".
14. Plug all peripheral devices and the AC power cable into the server.
15. Power up the server.
Removing and Installing 4x3.5" Hotswap Hard Drive
Cage Assembly
/
NOTE
This procedure applies only to the Intel
drive cage configuration.

Removing 4x3.5" Hotswap Hard Drive Cage with Backplane

1.
Observe the safety and ESD precautions at the beginning of this book.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the chassis cover. For instructions, see "Removing the Chassis Cover".
4.
Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel".
5.
Disconnect the power and data cables to the backplane.
®
Intel
Server Chassis P4000M Service Guide

Figure 46. Securing the 2.5" HDD on Fixed HDD Carrier Tray

Figure 47. Inserting the HDD Carrier Tray

®
Server Chassis P4000M family with 4x3.5'' hotswap hard disk
Hardware Installations and Upgrades
29

Advertisement

Table of Contents
loading

Table of Contents