Intel SC5650BCDP Technical Product Specification

Server system
Hide thumbs Also See for SC5650BCDP:
Table of Contents

Advertisement

Intel® Server System SC5650BCDP
Technical Product Specification
Intel order number: E80367-002
Revision 1.5
March 2010
Enterprise Platforms and Services Division – Marketing

Advertisement

Table of Contents
loading

Summary of Contents for Intel SC5650BCDP

  • Page 1 Intel® Server System SC5650BCDP Technical Product Specification Intel order number: E80367-002 Revision 1.5 March 2010 Enterprise Platforms and Services Division – Marketing...
  • Page 2: Revision History

    ® Revision History Intel Server System SC5650BCDP TPS Revision History Date Revision Modifications Number August 2009 Initial Release March 2010 Adding support for Intel® Xeon® processors 5600 series Intel order number: E80367-002 Revision 1.5...
  • Page 3 Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right.
  • Page 4: Table Of Contents

    ® Table of Contents Intel Server System SC5650BCDP TPS Table of Contents 1. Introduction .......................... 1 Server Board Use Disclaimer .................. 1 Server Board Use Disclaimer .................. 1 2. Product Overview......................... 2 System Views ......................4 System Dimensions ....................4 System Components ....................
  • Page 5 ® Intel Server System SC5650BCDP TPS Table of Contents Hot Swap Hard Disk Drive Bays ................34 5.3.1 Fixed Hard Drive Bay..................... 34 6. Standard Control Panel ..................... 36 Control Panel ......................36 7. PCI Cards and Assembly....................38 8. Environmental and Regulatory Specifications ..............39 System Level Environmental Limits ...............
  • Page 6 List of Figures ® Figure 1. Intel Server System SC5650BCDP................4 ® Figure 2. Intel Server System SC5650BCDP Components ............5 Figure 3. ATX 2.2 I/O Aperture ..................... 6 ® Figure 4. Intel Server Board S5500BC picture ................7 ®...
  • Page 7 ® Table 2. Intel Server System SC5650BCDP Dimensions ............4 ® Table 3. Intel Server System SC5650BCDP Components Reference ........5 Table 4. Board Layout reference ....................8 ® Table 5. Intel Light-Guided Diagnostic LED reference .............. 10 Table 6. Thermal Environmental Requirements ................. 13 Table 7.
  • Page 8 ® List of Tables Intel Server System SC5650BCDP TPS Table 32. System Environmental Limits Summary ..............39 Table 33. System Maintenance Procedure Times ..............40 Table 34. Product Safety & Electromagnetic (EMC) Compliance ..........42 Table 35. Product Ecology Compliance Reference Table ............47 Table 36.
  • Page 9 ® Intel Server System SC5650BCDP TPS List of Tables < This page intentionally left blank. > Revision 1.5 Intel order number: E80367-002...
  • Page 11: Introduction

    Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of supported components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions.
  • Page 12: Product Overview

    2. Product Overview ® ® The Intel Server System SC5650BCDP is a 5U server system which integrates the Intel ® Server Board S5500BC into the Intel Server Chassis SC5650DP. The server system features are designed to support the high-density server market. This chapter provides a high-level overview of the system features.
  • Page 13 Fan Fault DIMM Fault CPU Fault 5V-STBY System State POST Code Diagnostics 600-W PFC Intel validated PSU with integrated cooling fan. Power Supply One tool-less, 120-mm chassis rear fan. Fans One tool-less 120-mm PCI fan. One tool-less 92-mm drive bay fan.
  • Page 14: System Views

    ® Product Overview Intel Server System SC5650BCDP TPS Feature Description On-board ServerEngines* LLC Pilot II Controller Server Management Integrated Baseboard Management Controller (Integrated BMC), IPMI 2.0 compliant Integrated Super I/O on LPC interface ® Support for Intel Server Management Software ®...
  • Page 15: System Components

    System Components ® Figure 2. Intel Server System SC5650BCDP Components ® Table 3. Intel Server System SC5650BCDP Components Reference Description Description Control panel controls and indicators Two half-height 5.25-in peripheral drive bays Internal hard drive bay cage (behind door) Security lock...
  • Page 16: I/O Panel

    ® The Intel Server System SC5650BCDP supports a rack mount configuration. The rack mount kit includes the chassis slide rails, rack handle, rack orientation label, screws, and manual. This rack mount kit is designed to meet the EIA-310-D enclosure specification. General rack compatibility is further described in the Server Rack Cabinet Compatibility Guide found at http://support.intel.com.
  • Page 17: Figure 4. Intel ® Server Board S5500Bc Picture

    ® Intel Server System SC5650BCDP TPS Product Overview ® Figure 4. Intel Server Board S5500BC picture Revision 1.5 Intel order number: E80367-002...
  • Page 18: 2.7.1 Server Board Connector And Component Layout

    ® Product Overview Intel Server System SC5650BCDP TPS 2.7.1 Server Board Connector and Component Layout The following figure shows the board layout of the server board. Each connector and major component is identified by a number or letter, and is described in Table 4..
  • Page 19: Intel ® Light-Guided Diagnostic Led Locations

    ® Intel Server System SC5650BCDP TPS Product Overview Description Description System fan 3 header Main power connector DIMM sockets for Channel A & B (Supports CPU_1) Power Supply Auxiliary Connector SSI 24-pin Front Panel connector System fan 2 header CPU_1 fan header CPU Power Connector ®...
  • Page 20: Table 5. Intel ® Light-Guided Diagnostic Led Reference

    ® Product Overview Intel Server System SC5650BCDP TPS ® Table 5. Intel Light-Guided Diagnostic LED reference Description Description Post-Code Diagnostic LEDs Status LED System ID LED HDD LED System Fan 3 Fault LED 5 VSB LED DIMM Fault LED System Fan 2 Fault LED...
  • Page 21: Power Sub-System

    ® Intel server systems SC5650BCDP. The 600-W power supply has eight outputs: 3.3V, 5V, 12V1, 12V2, 12V3, 12V4, -12V and 5VSB. This form factor fits into a pedestal system and provides a wire harness output to the system. An IEC connector is provided on the external face for AC input to the power supply.
  • Page 22: Mechanical Overview

    ® Power Sub-System Intel Server System SC5650BCDP TPS 3.1.1 Mechanical Overview Figure 7. Mechanical Drawing for Power Supply Enclosure Intel order number: E80367-002 Revision 1.5...
  • Page 23: Airflow And Temperature

    ® Intel Server System SC5650BCDP TPS Power Sub-System 3.1.2 Airflow and Temperature The power supply incorporates one 80-mm fan for self and system cooling. The fan provides no less than 14 CFM of airflow through the power supply when installed in the system. The cooling air enters the power module from the non-AC side.
  • Page 24: Figure 8. Output Cable Harness For 600-W Power Supply

    ® Power Sub-System Intel Server System SC5650BCDP TPS Figure 8. Output Cable Harness for 600-W Power Supply NOTES: 1. ALL DIMENSIONS ARE IN MM 2. ALL TOLERANCES ARE +10 MM / -0 MM 3. INSTALL 1 TIE WRAP WITHIN 12MM OF THE PSU CAGE 4.
  • Page 25: Table 7. Cable Lengths

    ® Intel Server System SC5650BCDP TPS Power Sub-System Table 7. Cable Lengths Length Number of From To Connector # Description (mm) Pins Power Supply cover exit Baseboard Power Connector hole Length Number of From To Connector # Description (mm) Pins...
  • Page 26: Table 9. P2 Processor 0 Power Connector

    ® Power Sub-System Intel Server System SC5650BCDP TPS Contact: Molex* 39-00-0059 or equivalent Table 9. P2 Processor 0 Power Connector Signal 18 AWG Color Signal 18 AWG Color Black +12V1 White Black +12V1 White Black +12V1 Brown Black +12V1 Brown 3.1.3.3...
  • Page 27: Ac Input Requirements

    ® Intel Server System SC5650BCDP TPS Power Sub-System +12V4 Blue/White Stripe Black Black +5Vdc 3.1.3.6 P9 Right-angle SATA Power Connector Connector Housing: JWT* F6002HS0-5P-18 or equivalent Contact: Table 13. P9 Right-angle SATA Power Connector Signal 18 AWG Color +3.3V Orange...
  • Page 28: Table 15. Ac Input Rating

    ® Power Sub-System Intel Server System SC5650BCDP TPS Table 15. AC Input Rating PARAMETER Rated Max Input Start up VAC Power Off Current Voltage (110) 90 V 100-127 V 140 V 10 A 85Vac +/- 75Vac +/- 4Vac 5Vac Voltage (220)
  • Page 29: Table 16. Ac Line Sag Transient Performance

    ® Intel Server System SC5650BCDP TPS Power Sub-System 3.1.4.5 AC In-rush AC line in-rush current does not exceed a 50A peak, cold start @ 20 degrees C and no damage @ hot start for up to one-quarter of the AC cycle, after which, the input current is no more than the specified maximum input current at 264Vac input.
  • Page 30: Dc Output Specifications

    ® Power Sub-System Intel Server System SC5650BCDP TPS 3.1.4.8 AC Line Fast Transient (EFT) Specification The power supply meets the EN 61000-4-5 directive and any additional requirements in IEC1000-4-5:1995 and the Level 3 requirements for surge-withstand capability, with the following conditions and exceptions: •...
  • Page 31: Table 18. Load Ratings

    ® Intel Server System SC5650BCDP TPS Power Sub-System The remote sense return (ReturnS) is able to regulate out a minimum of 200mV drop in the power ground return. The current in any remote sense line is less than 5mA to prevent voltage sensing errors.
  • Page 32: Table 19. Voltage Regulation Limits

    ® Power Sub-System Intel Server System SC5650BCDP TPS 3.1.5.6 Voltage Regulation The power supply output voltages are within the following voltage limits when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise. All outputs are measured with reference to the return remote sense signal (ReturnS). The +12V3, +12V4, –12V and 5VSB outputs are measured at the power supply connectors...
  • Page 33: Table 21. Capacitive Loading Conditions

    ® Intel Server System SC5650BCDP TPS Power Sub-System 3.1.5.8 Capacitive Loading The power supply is stable and meets all requirements with the following capacitive loading ranges. Table 21. Capacitive Loading Conditions Output Units μF +3.3V 12,000 12,000 μF +12V(1, 2, 3)
  • Page 34: Table 22. Ripple And Noise

    ® Power Sub-System Intel Server System SC5650BCDP TPS Table 22. Ripple and Noise +3.3V +12V(1,2,3,4) -12V +5VSB 50mVp-p 50mVp-p 120mVp-p 120mVp-p 50mVp-p 3.1.5.13 Timing Requirements The timing requirements for power supply operation are as follows. The output voltages must rise from 10% to within regulation limits (T...
  • Page 35: Figure 9. Output Voltage Timing

    ® Intel Server System SC5650BCDP TPS Power Sub-System Vout Vout vout_off vout rise vout_on Figure 9. Output Voltage Timing Table 24. Turn On / Off Timing Item Description Minimum Maximum Units Delay from AC being applied to 5VSB being within...
  • Page 36: Protection Circuits

    ® Power Sub-System Intel Server System SC5650BCDP TPS AC Input vout_holdup Vout pwok_low AC_on_delay pwok_off sb_on_delay pwok_on pwok_off sb_on_delay pwok_on PWOK pson_pwok pwok_holdup 5VSB sb_vout 5VSB holdup pson_on_delay PSON AC turn on/off cycle PSON turn on/off cycle Figure 10. Turn On/Off Timing (Power Supply Signals) 3.1.6...
  • Page 37: Table 25. Over Current Protection (Ocp)

    ® Intel Server System SC5650BCDP TPS Power Sub-System Table 25. Over Current Protection (OCP) VOLTAGE OVER CURRENT LIMIT +3.3V 26.4A 26.4A +12V1 +12V2 +12V3 +12V4 -12V 0.625A 5VSB 3.1.7.1 Over Voltage Protection (OVP) The power supply over voltage protection is locally sensed. The power supply will shut down and latch off after an over voltage condition occurs.
  • Page 38: Figure 11. Pson# Required Signal Characteristics

    ® Power Sub-System Intel Server System SC5650BCDP TPS 3.1.7.3 PSON# Input Signal The PSON signal is required to remotely turn on/off the power supply. PSON is an active low signal that turns on the +3.3V, +5V, +12V, and -12V power rails. When this signal is not pulled low by the system, or left open, the outputs (except the +5VSB) turn off.
  • Page 39: Fru Data

    ® Intel Server System SC5650BCDP TPS Power Sub-System Signal Type Open collector/drain output from power supply. Pull-up to VSB located in system. PWOK = High Power OK PWOK = Low Power Not OK Logic level low voltage, Isink=4mA 0.4V 2.4V 5.25V...
  • Page 40: Cooling Sub-System

    ® sensor for BMC control. The Intel Server Board S5500BC BMC controller may use the TMP75 sensor to adjust fan speeds according to air intake temperatures. Refer to the Intel ® Server Board S5500BC Technical Product Specification for configuring information.
  • Page 41: System Fan Connectors

    Active heatsinks for CPUs incorporate a fan to provide cooling. The Intel Server System SC5650BCDP is engineered to work with processors that have an active heatsink solution. Heatsink thermal solutions are sold separately, be sure that you use one that is rated for the wattage of your processor.
  • Page 42: Table 29. Cpu And System Fan Connector Pin-Out

    ® Cooling Sub-System Intel Server System SC5650BCDP TPS The pin configuration for each fan connector is identical. The following table provides pin-out information. CPU and System Fan Connector Pin-out Table 29. (Location: J3K1, J7K2, J3K2, J8K3, J8B4) Signal Name Type...
  • Page 43: Peripheral And Hard Drive Support

    ® Intel Server System SC5650BCDP supports one 3.5-in removable media peripheral, such as a tape drive, below the 5.25-in peripheral bays. The bezel must be removed prior to installing a 3.5-in removable media devise. When a drive is not installed, a snap-in EMI shield must be in place to ensure regulatory compliance.
  • Page 44: Hot Swap Hard Disk Drive Bays

    Fixed Hard Drive Bay ® Intel Server System SC5650BCDP comes with a removable hard drive bay that can accept up to six cabled 3.5-in x 1-in hard drives. Power requirements for each individual hard drive may ® limit the maximum number of drives that can be integrated into an Intel Server System SC5650BCDP.
  • Page 45: Figure 14: Fixed Hard Drive Bay

    ® Intel Server System SC5650BCDP is capable of accepting a single SAS/SATA hot swap backplane hard drive enclosure in place of the fixed drive bay. Both backplanes (expanded and non-expanded) have a connector to accommodate a SAF-TE controller on an add-in card. Each backplane type supports up to six 1-in hot swap drives when mounted in the docking drive carrier.
  • Page 46: Standard Control Panel

    6. Standard Control Panel ® The Intel Server System SC5650BCDP control panel configuration has three buttons and five LEDs. When the hot-swap drive bay is installed, a bi-color hard drive LED is located on each drive carrier (six totals) to indicate specific drive failure or activity. These LEDs are visible upon opening the front bezel door.
  • Page 47: Table 31. Control Panel Led Functions

    ® Intel Server System SC5650BCDP TPS Standard Control Panel Table 31. Control Panel LED Functions LED Name Color Condition Description Power/Sleep LED Green Power on Power off LAN # 1- Green Linked Link/Activity BLINK LAN activity Disconnected LAN # 2-...
  • Page 48: Pci Cards And Assembly

    ® PCI Cards and Assembly Intel Server System SC5650BCDP TPS 7. PCI Cards and Assembly ® The Intel Server Board S5500BC integrated into this system provides five PCI slots: • Slot3: One half-length (6.6 inches) PCI Express* x4 connector with x4 link width •...
  • Page 49: Environmental And Regulatory Specifications

    5 Hz to 500 Hz, 2.20 g RMS random Shock, operating Half sine, 2 g peak, 11 mSec ESD* +/-15 KV except I/O port +/-8 KV per the Intel Environmental test specification System Cooling 2550 BTU/hour Requirement in BTU/Hr * IMPORTANT NOTES: ®...
  • Page 50: Replacing The Cmos Battery

    ® Environmental and Regulatory Specifications Intel Server System SC5650BCDP TPS Table 33. System Maintenance Procedure Times Activity Time Estimate Remove cover 1 min Remove and replace hard disk drive 5 min Remove and replace power supply module 1 min Remove and replace system fan...
  • Page 51: Product Regulatory Compliance

    Updated product information for configurations can be found on the Intel Server Builder Web site at http://www.intel.com/go/serverbuilder. If you do not have access to Intel’s Web address, please contact your local Intel representative. • Server chassis (base chassis is provided with power supply and fans)⎯UL listed.
  • Page 52: Table 34. Product Safety & Electromagnetic (Emc) Compliance

    ® Environmental and Regulatory Specifications Intel Server System SC5650BCDP TPS The following table references Server Chassis Compliance and markings that may appear on the product. Markings below are typical markings however, may vary or be different based on how certification is obtained.
  • Page 53 ® Intel Server System SC5650BCDP TPS Environmental and Regulatory Specifications Compliance Regional Compliance Compliance Reference Marking Example Description Reference Japan VCCI Certification Korea RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) 인증번호: CPU-Model Name (A) Russia GOST-R Certification...
  • Page 54: Electromagnetic Compatibility Notices

    ® Environmental and Regulatory Specifications Intel Server System SC5650BCDP TPS Electromagnetic Compatibility Notices 8.6.1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 55: Fcc Verification Statement

    ® Intel Server System SC5650BCDP TPS Environmental and Regulatory Specifications 8.6.2 FCC Verification Statement Product Type: SR1630; S5500BC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 56: Bsmi (Taiwan)

    The CCC Certification Marking and EMC warning is located on the outside rear area of the product. Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel’s product ecology compliance criteria.
  • Page 57: Table 35. Product Ecology Compliance Reference Table

    Not applied to internal packaging such as plastics, foams, etc. Intel Internal All materials, parts and subassemblies must not Specification contain restricted materials as defined in Intel’s Environmental Product Content Specification of None Required Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm...
  • Page 58 German Green Dot Applied to Retail Packaging Only for Boxed Boards Intel Internal All materials, parts and subassemblies must not Specification contain restricted materials as defined in Intel’s Environmental Product Content Specification of None Required Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm International ISO11469 - Plastic parts weighing >25gm are...
  • Page 59: Other Markings

    ® Intel Server System SC5650BCDP TPS Environmental and Regulatory Specifications Other Markings Compliance Compliance Reference Compliance Reference Description Marking Example Stand-by Power 60950 Safety Requirement Applied to product is stand-by power switch is used. Multiple Power Cords 60950 Safety Requirement...
  • Page 60: Appendix A: Integration And Usage Tips

    Appendix A: Integration and Usage Tips ® This section provides a list of useful information unique to the Intel Server System SC5650BCDP that you should keep in mind while integrating the server system. • ® The Intel Server System SC5650BCDP requires the use of a shielded LAN cable to comply with Immunity regulatory requirements.
  • Page 61: Appendix B: Post Code Diagnostic Led Decoder

    ® Intel Server System SC5650BCDP TPS Appendix B: POST Code Diagnostic LED Decoder Appendix B: POST Code Diagnostic LED Decoder The BIOS executes platform configuration processes during the system boot. Each process is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code on the POST Code Diagnostic LEDs on the back edge of the server board.
  • Page 62: Table 37. Diagnostic Led Post Code Decoder

    ® Appendix B: POST Code Diagnostic LED Decoder Intel Server System SC5650BCDP TPS Table 37. Diagnostic LED POST Code Decoder Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description Multi-use code – This POST Code is used in different contexts...
  • Page 63 ® Intel Server System SC5650BCDP TPS Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description 0x51h Allocating resources to PCI buses 0x52h Hot Plug PCI controller initialization 0x53h Reserved for PCI bus...
  • Page 64 ® Appendix B: POST Code Diagnostic LED Decoder Intel Server System SC5650BCDP TPS Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description 0xD3 Trying to boot device selection 3 0xD4 Trying to boot device selection 4...
  • Page 65: Appendix C: Post Error Messages And Handling

    ® Intel Server System SC5650BCDP TPS Appendix C: POST Error Messages and Handling Appendix C: POST Error Messages and Handling Whenever possible, the BIOS outputs the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information.
  • Page 66 ® Appendix C: POST Error Messages and Handling Intel Server System SC5650BCDP TPS Error Code Error Message Response 0195 Processor 0x Intel(R) QPI speed mismatch. Major 0196 Processor 0x model mismatch. Fatal 0197 Processor 0x speeds mismatched. Fatal 0198 Processor 0x family is not supported.
  • Page 67 ® Intel Server System SC5650BCDP TPS Appendix C: POST Error Messages and Handling Error Code Error Message Response 854B DIMM_F2 Disabled. Major 8560 DIMM_A1 Component encountered a Serial Presence Detection (SPD) fail error. Major 8561 DIMM_A2 Component encountered a Serial Presence Detection (SPD) fail error.
  • Page 68: Table 40. Post Error Beep Codes

    ® Appendix C: POST Error Messages and Handling Intel Server System SC5650BCDP TPS Error Code Error Message Response 9506 ATA/ATPI component encountered a controller error. Minor 95A6 PCI component encountered a controller error. Minor 95A7 PCI component encountered a read error.
  • Page 69 ® Intel Server System SC5650BCDP TPS Appendix C: POST Error Messages and Handling In case of POST error(s) listed as Major, the BIOS enters the error manager and waits for the user to press an appropriate key before booting the operating system or entering the BIOS Setup.
  • Page 70: Glossary

    ® Glossary Intel Server System SC5650BCDP TPS Glossary Word / Acronym Definition Australian Communication Authority ANSI American National Standards Institute Baseboard Management Controller CMOS Complementary Metal Oxide Silicon DC-to-DC Emergency Management Port Front Panel Fault Resilient Boot Field Replaceable Unit...
  • Page 71: Reference Documents

    ® Intel Server System SC5650BCDP TPS Reference Documents Reference Documents • ® Intel Server Board S5500BC Technical Product Specification • ® Intel Server Chassis SC5650 Technical Product Specification • ® ® ® Intel Server Board S5500BC / Intel Server Chassis SC5650 / Intel...