1)
Fit the edges of the EMI shield against the sides of the chassis (see letter A).
2)
While pressing the EMI shield, slide the EMI Shield downwards until the latches on the EMI
shield are engaged with the chassis (see letter B).
6.
Install the 4x3.5'' Hotswap Hard Drive Cage.
1)
Slide the 4x3.5'' Hotswap Drive Cage into the slot (see letter A).
2)
Secure the Hard Drive Cage with the Screw (see letter B).
7.
Make the backplane and server board/RAID controller card cable connections. Refer to the
documentation that came with your server board and/or RAID controller card for instructions on
connecting backplane cables to your server board or RAID controller card.
1)
Connect data cables (letter A).
2)
Connect an I2C_IN cable (letter B).
3)
Connect an SGPIO cable (letter C).
®
Intel
Server Chassis P4000M Service Guide
Figure 50. Installing the EMI shield
Figure 51. Installing the 4x3.5
Hardware Installations and Upgrades
Hotswap Hard Drive Cage
''