Removing And Installing The Hotswap Hdd Emi Shield; Removing The Hotswap Hdd Emi Shield; Figure 62. 8X2.5" Hot Swap Backplane Cable Connections - Intel P4000M Service Manual

Server chassis family
Table of Contents

Advertisement

Hardware Installations and Upgrades
7.
Install the front bezel. For instructions, see "Installing the Front Bezel (Pedestal Only)".
8.
Install the air duct if the air duct is removed. For instructions, see "Installing the Airduct"
9.
Install the chassis cover. For instructions, see "Installing the Chassis Cover".
10. Plug all peripheral devices and the AC power cable into the server.
11. Power up the server.

Removing and Installing the Hotswap HDD EMI Shield

/
NOTE
This procedure applies only to the Intel
drive cage configuration.

Removing the Hotswap HDD EMI Shield

1.
Observe the safety and ESD precautions at the beginning of this book.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the chassis cover. For instructions, see "Removing the Chassis Cover".
4.
Remove the front bezel. For instructions, see "Removing the front bezel (Pedestal Only)".
5.
Remove the 8x2.5'' Hotswap HDD cage. For instructions, see "Removing 8x2.5'' Hotswap Hard Disk
Drive Cage with Backplane"
6.
Lift the EMI shield (see letter A) and move EMI shield outward from the chassis (see letter B).
40

Figure 62. 8x2.5" Hot Swap Backplane Cable Connections

®
Server Chassis P4000M family with 8x2.5'' hotswap hard disk
®
Intel
Server Chassis P4000M Service Guide

Advertisement

Table of Contents
loading

Table of Contents