Installing 4x3.5" Hotswap Backplane

1.
Observe the safety and ESD precautions at the beginning of this book.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the chassis cover. For instructions, see "Removing the Chassis Cover".
4.
Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel".
5.
Remove the 4x3.5'' Hotswap Hard drives cage. For instructions, see "Removing 4x3.5'' Hotswap Hard
Drive Cage".
6.
Attach the backplane to the back side of the hotswap drive cage, and make sure the hooks on the
cage are inserted in the backplane holes (see letter A).
7.
Push the backplane (see letter B) and secure the backplane with the screw (see letter C).
8.
Install the 4x3.5'' Hotswap Hard drives cage. For instructions, see "installing 4x3.5'' Hotswap Hard
Drive Cage".
9.
Install the front bezel. For instructions, see "Installing the Front Bezel".
®