Intel P4304SC2SFEN User Manual

Server system p4000sc family

Advertisement

Quick Links

Intel® Server System P4000SC Family
Quick Installation User's Guide
Thank you for buying an Intel® Server System. The following information will help you
assemble your Intel ® Server System and install components.
If you are not familiar with ESD [Electrostatic Discharge] procedures used during
system integration, see the complete ESD procedures described in your Service Guide.
This guide and other supporting documents are located on the web at:
http://www.intel.com/support.
G63272-001

Advertisement

Table of Contents
loading

Summary of Contents for Intel P4304SC2SFEN

  • Page 1 Intel® Server System P4000SC Family Quick Installation User's Guide Thank you for buying an Intel® Server System. The following information will help you assemble your Intel ® Server System and install components. If you are not familiar with ESD [Electrostatic Discharge] procedures used during system integration, see the complete ESD procedures described in your Service Guide.
  • Page 2 (This page is intentionally left blank.)
  • Page 3: Table Of Contents

    Install Tool-less CD-ROM or DVD-ROM Drive ............5 Install Hard Drive ......................... 6 Install PCI-e Card Assembly ................... 7 Install Intel® Remote Management Module 4 NIC (optional) ....... 9 Install RMM4 EMI Cover (optional) ................9 Install Alternate Serial Port (optional) ..............9 Install Intel®...
  • Page 4: System Fan

    Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2012, Intel Corporation. All rights reserved.
  • Page 5: System Overview

    System Overview Intel® Server System P4304SC2SFEN System Features and Components 550W Fixed Power Supply I/O Ports Alternate RMM4 Knockout PCI Add-in Board Slot Covers AC Input Power Connector Serial Port Knockout A Kensington* Cable Lock Mounting Hole Padlock Loop RMM4 Knockout Front Control Panel 5.25"...
  • Page 6 System Overview Intel® Server System P4308SC2MHGC System Features and Components 750W Hot Swap Power Supply (Two) AC Input Power Connector (Two) I/O Ports Alternate RMM4 Knockout PCI Add-in Board Slot Covers RMM4 Knockout Alternate Serial Port Knockout A Kensington* Cable Lock Mounting Hole...
  • Page 7: General Installation Process

    General Installation Process The installation instructions in this section are for general components of Intel® Server System P4000SC family, but the illustrations are based on the Intel® Server System P4308SC2MHGC. Minimum Hardware Requirements Preparing the System To avoid integration difficulties and possible damage to your system, make sure you have components from each category below.
  • Page 8: Install Heat Sink(S)

    General Installation Process Install the Processor(s) ... continued B. Open the Load Plate C. Remove the Processor D. Install the Processor Protective Cover Push the rear tab with your finger tip to bring the CAUTION: The underside front end of the load plate up slightly. of the processor has Take the processor out of the components that may damage...
  • Page 9: Install Dimm Memory Modules

    ® shown. S2400SC at: http://www.intel.com/support/motherboards/server DDR3 Other Memory sizing and configuration is supported only for qualified DIMMs approved by Intel . For a list of ® Memory supported memory, see the tested memory list at: http://serverconfigurator.intel.com/default.aspx Install DIMM Memory Modules ... Continued...
  • Page 10: Install Hard Drive

    General Installation Process Install Hard Drive Fixed Hard Drive Carrier (For chassis with fixed hard drive bay only) A. Remove the EMI B. Install the Hard Disk Drive C. Install the EMI shield shield Press the clip. Pull out the HDD Secure the 3.5"...
  • Page 11: Install Pci-E Card Assembly

    General Installation Process Install PCI-e Card Assembly (For P4308SC2MHGC) Remove the PCI-e slot shield by pushing the Rotate the shield out from inside the chassis. PCI-e retainer all the way to Install the optional PCI-e card bracket with open. screws. The card bracket helps to hold double width cards.
  • Page 12 General Installation Process Install PCI-e Card Assembly (For P4304SC2SFEN and P4304SC2SHDR) Remove the PCI slot shield by pushing the From inside of chassis, press open the back While holding the PCI add-in board by its top edge or shield out from inside the chassis.
  • Page 13: Install Intel® Remote Management Module 4 Nic (Optional)

    CAUTION: Carefully remove the knock out with screwdriver, directly removing it with finger has potential risk. ® Connect the cable to the cable connector on the Intel Dedicated Server Management NIC module. Mount the NIC module to the rear panel of the chassis and secure the bracket with two screws.
  • Page 14: Install Intel® Raid Smart Battery (Optional)

    General Installation Process Install Intel® RAID Smart Battery (optional) For P4304SC2SFEN & P4304SC2SHDR For P4308SC2MHGC Align the tabs on the plastic battery holder with the mounting holes in the chassis and slide the plastic battery holder toward the front of the chassis until the tabs engage with the mounting holes.
  • Page 15: Install Air Duct

    BIOS version. Compare this to the versions at: your keyboard, mouse, http://www.intel.com/support video, and other I/O cables. If new versions are available, update the BIOS on your server. See the User Guide on the Intel Server Deployment and ® Connect the AC Management DVD for update instructions.
  • Page 16: Reference

    Reference HDD Cage Cable Connection NOTE: Refer to the documents which come with your server board and/or RAID controller card for instructions on connecting backplane cables to your server board or RAID controller card. 4 x 3.5" HDD Cage 8 x 3.5" HDD Cage Connect the I C cable to I C_IN connector on backplane.
  • Page 17: Front Panel Controls And Indicators

    NIC LED System Power Button with Power LED ID Button with ID LED Integrated System Reset Button HDD Activity LED Cable Routing Diagram Figure 1 Figure 2 (P4304SC2SHDR and P4304SC2SFEN) (P4304SC2MHGC) Power Supply Power Supply CPU2 CPU2 Server Board CPU1...
  • Page 18 G63272-001...

This manual is also suitable for:

P4304sc2shdrP4308sc2mhgc

Table of Contents