6.18 Error Reports
In the event of an error, either a summary or a full error report is displayed at
the console. Error reports are specified by setting the d_report environment
variable. See Example 6-20 and Example 6-21.
Example 6-20 Sample Summary Error Report
P00>>> set d_report summary
P00>>> test kzmsa
Configuring kzmsa...
Testing kzmsa
Type Ctrl/C to abort
Initializing KZMSA
kzmsa self-test passed
Starting device exerciser on duc1.0.0.12.0 (id #20)
Starting device exerciser on duc2.0.0.12.0 (id #21)
Starting device exerciser on duc4.0.0.12.0 (id #22)
Bad MSCP status (4|0) received
Failed to send Read to duc4.0.0.12.0
*** Hard Error - Error #1 on FRU: duc4.0.0.12.0
Error in read of 2097152 bytes at location 07E00000 from duc4.0.0.12.0.
ID
Program
--------
-------
481
dsk_ex
***End of Error***
6-50
AlphaServer 8200/8400 Operations Manual
# Command to set the type of error
# report to summary (default).
# Command to test the kzmsa adapter
# and its devices.
Device
--------------
-------
duc4.0.0.12.0
Pass Hard/Soft Test
---
---
---
18
1
0
Time
--------
1 12:07:01