HP ProCurve 2810 Series Management And Configuration Manual page 124

Hide thumbs Also See for ProCurve 2810 Series:
Table of Contents

Advertisement

Interface Access and System Information
Interface Access: Console/Serial Link, Web, and Telnet
7-6
To re-enable inbound Telnet access:
ProCurve(config)# telnet-server
Outbound Telnet to Another Device. This feature operates indepen­
dently of the telnet-server status and enables you to Telnet to another device
that has an IP address.
Syntax:
telnet < ip-address >
For example:
ProCurve# telnet 10.28.27.204
Reconfigure Web Browser Access. In the default configuration, web
browser access is enabled.
Syntax: [no] web-management
To disable web browser access:
ProCurve(config)# no web-management
To re-enable web browser access:
ProCurve(config)# web-management
Reconfigure the Console/Serial Link Settings. You can reconfigure one
or more console parameters with one console command.
Syntax:
console
[terminal <vt100 | ansi>]
[screen-refresh <1 | 3 | 5 | 10 | 20 | 30 | 45 | 60>]
[baud-rate
<speed-sense | 1200 | 2400 | 4800 | 9600 | 19200 |38400 | 57600>]
[flow-control <xon/xoff | none>]
[inactivity-timer <0 1 5 10 15 20 30 60 120>]
[events <none | all | non-info | critical | debug]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents