N o t e
Figure 7-3. Example of Executing the Console Command with Multiple Parameters
If you change the Baud Rate or Flow Control settings for the switch, you
should make the corresponding changes in your console access device. Oth
erwise, you may lose connectivity between the switch and your terminal
emulator due to differences between the terminal and switch settings for these
two parameters.
Changes to console parameters require that you perform a write memory and
then execute boot before the new console configuration will take effect. To
enable temporary and non-disruptive changes to the terminal mode without
requiring a reboot, use the console local terminal command (see page 7-8).
For example, to use one command to configure the switch with the following:
■
VT100 operation
19,200 baud
■
No flow control
■
■
10-minute inactivity time
Critical log events
■
you would use the following command sequence:
The switch implements the Event Log change immediately. The switch implements
the other console changes after executing
Interface Access and System Information
Interface Access: Console/Serial Link, Web, and Telnet
write memory
reload
and
.
7-7