Code 16K

Syntax:
c9

Code 49

Syntax:
c10

POSTNET

Syntax:
c11
Notes:
POSTNET uses the height (h) and width (w) commands in the same way as a
font. Other symbologies use "h" to specify the bar height and "w" to specify
the narrow bar width. POSTNET uses "h" and "w" to magnify the base
character cell. Each character cell is 13 dots high by 22 dots wide. The default
width and height magnification for POSTNET is 2 x 2, resulting in a symbology
sized according to the POSTNET specification.

PDF417

Syntax:
c12[,[ m1 ][ ,m2 ][ ,m3 ]]
Default:
,m1 = 0
,m2 = 9
,m3 = 0
Notes:
PDF417 is a stacked 2D symbology that provides the ability to scan across rows
of code. Each row consists of start/stop characters, row identifiers, and symbol
characters, which consist of four bars and four spaces each and contain the
actual data. This symbology uses error correction symbol characters appended
at the end to recover loss of data.
Selecting the Number of Columns
Set ,m1 to zero to have the printer select a height magnification that is three
times the width magnification for the symbol. The specifications of PDF417
recommend these magnification values for creating a symbol that you can scan
easily.
Printer selects the number of columns needed to create a symbol
that is as close to square as possible. The range for m1 is 0 to 30.
The printer automatically selects the error correction level based on
the amount of data. The range for ,m2 is 0 to 9.
Truncating disabled. The values for ,m3 are 0 and 1.
Program Mode Commands
6
6-43