Maintenance
Operating Instructions D887 - 00.0 - 10/2022
Important
The released amount of oil does not change until the operating
time has run a few minutes. Sew for several minutes before you
check the setting again.
6.3

Servicing the pneumatic system

6.3.1

Adjusting the operating pressure

NOTICE
Property damage from incorrect adjustment!
Incorrect operating pressure can result in damage to
the machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
Proper setting
Refer to the Technical Data ( p. 203) chapter for the permis-
sible operating pressure. The operating pressure cannot deviate
by more than ±0.5 bar.
Check the operating pressure on a daily basis.
Fig. 73: Adjusting the operating pressure
(1) - Pressure regulator
To adjust the operating pressure:
1.
Pull the pressure regulator (1) up.
(2) - Pressure gage
149