Using This
Control:
Does This:
Control Unit
Establishes where control unit power is controlled.
Local/Remote
On Printer 1 - When this switch is in the Local position, the PUM is
Switch
powered on and off by the Control Unit Power On and the Control
Unit Power Off if in Local switches. In the Remote position, the PUM
is powered on and off by Printer 2 control unit power controls.
On simplex printers and Printer 2 of a duplex configuration - When
this switch is in the Local position, the AFCCU is powered on and off
by the Control Unit Power On and the Control Unit Power Off if in
Local switches. In the Remote position, the AFCCU is powered on and
off by the controlling computer system.
Printer
Establishes where printer power is controlled. When this switch is in
Local/Remote
the Local position, the printer is powered on and off by the Printer
Switch
Power On and the Printer Power Off if in Local switches. In the
Remote position, the printer is powered on and off by the Control Unit
Power On and Control Unit Power Off If In Local switches on this
panel.
Control Unit
Powers on the AFCCU frame or the PUM frame when the Control Unit
Power On
Local/Remote switch is set to Local.
Switch
Printer Power
Powers on the printer when the Printer Local/Remote switch is set to
On Switch
Local.
Control Unit
Powers off the AFCCU when the Control Unit Local/Remote switch is
Power Off If In
set to Local.
Local Switch
Printer Power
Powers off the printer when the Printer Local/Remote switch is set to
Off If In Local
Local.
Switch
Emergency
On Printer 1 - When set to Power Enable, the PUM and printer engine
Power Off
can be powered on by Local or Remote control. Power Off does an
Switch
emergency shutdown.
On simplex printers and Printer 2 of a duplex configuration - When
set to Power Enable, the AFCCU and printer engine can be powered on
by Local or Remote control. Power Off does an emergency shutdown.
All power is removed from the system.
Attention!
Using the Unit Emergency Power Off switch can cause loss of
data and hardware problems; therefore, you should use it only in
an emergency.
Chapter 3. Functional Areas
19