Table 16. Printer Configuration Items (continued)
Configuration Item
Description
Preheat Platen
This entry allows setting the preheat platen temperature
Temperature
to a higher or lower temperature than the default as
needed for different types of forms. If 0 (zero) is entered
for the preheat platen temperature under Define Forms,
the temperature set under Configure Printer is used.
For Models ED1/ED2, a temperature must be set for
Printer 1 and Printer 2.
Scan Factory Adjust
(CE Change Only) This is used by service personnel to
for Printer 1
adjust the scan direction printing registration.
Process Factory
(CE Change Only) This is used by service personnel to
Adjust for Printer 1
adjust the process direction printing registration.
Scan Factory Adjust
(CE Change Only) This is used by service personnel to
for Printer 2 (D)
adjust the scan direction printing registration.
Process Factory
(CE Change Only) This is used by service personnel to
Adjust for Printer 2
adjust the process direction printing registration.
(D)
Beam 1 offset
(CE Change Only). This is used by maintenance
adjustment
personnel to control the vertical alignment or horizontal
adjustment of the separate beams of a multi-beam printer.
Beam 2 offset
(See information in Beam 1 offset adjustment)
adjustment
Beam 3 offset
(See information in Beam 1 offset adjustment)
adjustment
Beam 4 offset
(See information in Beam 1 offset adjustment)
adjustment
Beam 5 offset
(See information in Beam 1 offset adjustment)
adjustment
(See information in Beam 1 offset adjustment)
Beam 1 offset
adjustment for
Printer 2 (D)
(See information in Beam 1 offset adjustment)
Beam 2 offset
adjustment for
Printer 2 (D)
Beam 3 offset
(See information in Beam 1 offset adjustment)
adjustment for
Printer 2 (D)
Beam 4 offset
(See information in Beam 1 offset adjustment)
adjustment for
Printer 2 (D)
Value Options
Range of 45 to 100°C — in
increments of 5°
Default is 80°C
Range of 0 to 100 units
Default is 40 units
Unit = 2 pels
Range of 0 to 60 units
Default is 15 units
Unit = 1 pel
Range of 0 to 100 units
Default is 40 units
Unit = 2 pels
Range of 0 to 60 units
Default is 15 units
Unit = 1 pel
Range of 0.0 to 15.9
Default is 8.0 units
Unit = .1 pel
(See information in Beam 1 offset
adjustment)
(See information in Beam 1 offset
adjustment)
(See information in Beam 1 offset
adjustment)
(See information in Beam 1 offset
adjustment)
(See information in Beam 1 offset
adjustment)
(See information in Beam 1 offset
adjustment)
(See information in Beam 1 offset
adjustment)
(See information in Beam 1 offset
adjustment)
Chapter 8. Configuring the System