APPENDIX E: COMBUSTION AIR SUPPLY

FOR MOBILE HOME INSTALLATION, IT IS MANDATORY TO CONNECT THE STOVE TO AN OUTSIDE
COMBUSTION AIR SOURCE. INSULATED PIPE SHOULD NEVER EXCEED 10 FEET.
It is recommended to install an outside air inlet in or near the room where the stove is installed.
When doing so, it is preferable to choose a wall which is not exposed to dominant winds, depending
on the conditions surrounding your house.
An insulated 3" inside diameter metallic pipe, either flexible or rigid, must be attached to the fresh air
intake (D).
To complete the installation, make a hole of 1/4" to 1/2" (6 mm à 13 mm) bigger than the insulate
pipe diameter in the outside wall of the house at the chosen location. From outside, place the outside
air inlet cap (E) in the hole (open side down) and fasten the register to the wall, with screw. Place the
insulated pipe (A) over the register tube and over the fireplace outside air connector (D). At each end,
carefully pull back the insulation and plastic cover, exposing the flexible pipe. Attach the flexible pipe
using pipe clamps(C). For a better seal, you may also use aluminum tape. Wrap the tape around the
joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic cover back
over the pipe. Fix the plastic in place using aluminum tape.
90
WARNING
AIR INLET
EXTERIOR WALL
INSULATED PIPE
AIR SUPPLY
Cambridge Pellet Stove Installation and Operation Manual