Connect Treated Water Line; Connect Drain Line - Cleveland SteamCraft V Service Manual

Counter type convection steamer
Table of Contents

Advertisement

Page 20
CET-16 Service Manual

Connect Treated Water Line

Connect Drain Line

d
Printe
4/90
Referring to Water Supply Lines (page 10) and Figure 2-3, verify that the
water supply fine has been extended from the SteamerGard water
treatment system to the SteamCraft V properly. Connect the treated water
supply line to the SteamCraft V as described below.
1. Refer to the SteamerGard installation manual and verify that it has
been installed properly for this application.
2. Verify that a check valve has been installed between the SteamerGard
water treatment system and the SteamCraft V.
3. Remove the SteamCraft V rear panel by removing six screws (figure 2-
15) that hold it in place. Save the screws.
4. Referring to figure 2-19, inspect the SteamCraft V to verify that the
treated water supply bulkhead coupling has been properly installed
and securely attached to the steam generator feed line inside the
steamer.
5. Flush the treated water supply Iine before connecting it to the steam
generator intake bulkhead coupling.
6. Apply pipe dope or teflon tape to the threads of the treated water
supply fine, and securely connect the supply fine to the steam gener-
ator intake bulkhead coupling.
7. Turn on the treated water supply, and check the lines for signs of
leakage, both outside and inside the steamer
8. If no further work is required inside the SteamCraft V, secure the rear
panel in place using six mounting screws (figure 2-l5).
Referring to Free Air Vented Drain Lines (page 11), verify that the drain
fines meet capacity and venting requirements. Connect the SteamCraft V
dram outlet to the outlet extension and drain fines as described below.
1. The SteamCraft V drain outlet (figure 2-20) is a 1-1/4" NPT pipe
protruding from the back of the unit. An elbow connects this drain
outlet to the drain extension pipe assembled during site preparation.
2. Refer to figure 2-20. The outlet extension fine has a free air vented
connection to floor drain or fines leading to the floor drain
3. When assembling the pipes and fittings of the drain outlet extension,
apply a hardening type pipe sealant to the threads, and thread them
together FINGER TIGHT ONLY. DO NOT USE A WRENCH.