Electric Power Line - Cleveland SteamCraft V Service Manual

Counter type convection steamer
Table of Contents

Advertisement

Electric Power Line

CET-16 Service Manual
Furnishing and installing the electrical power Iines, switches, fuse boxes,
connectors and their accessories is the responsibility of the owner and/or
installer. Figure 2-6 illustrates an electrical layout recommended by
Cleveland Range. When installing the electrical power lines and acces-
sories, observe the following instructions.
1. In the United States, install the electrical power lines in accordance
with local codes and/or the National Electric Code, ANSI/NFPA No.
70-1990 (USA).
2. In Canada, install the electrical power lines in accordance with local
codes and/or the Canadian Electrical Code, CSA Standard C22.1
(Canada).
3. Install the proper size disconnect switch, circuit breaker or fuses, and
wire and conduit to conform to all local codes and the national codes
cited above. See table 2-3 for wire requirements.
Table 2-3. Minimum Wire Requirements
LIN
E
VOLTAGE
208
220
240
380/220
415/240
440
480
*All 3 Phase
**Use copper wire rated for 75° C.
Page 9
KILO
LIN
E
WATTS
AMPS*
16.7
46
153
40
18.0
43
153
23
18.0
25
153
20
18.0
22
WIRE
GAUGE**
6
6
6
10
10
10
10
Printed 4/90