Connect Electrical Line - Cleveland SteamCraft V Service Manual

Counter type convection steamer
Table of Contents

Advertisement

Connect Electrical Line

Figure 2-15. Rear Panel Removal
Referring to Electric Power Line (page 9), verify that the electric power
lines have been extended to the SteamCraft V properly. Connect them to
the terminal block inside the rear cover as described below.
1. Move the SteamCraft V so the rear panel can be easily reached.
2. Remove the rear panel by removing six screws (figure 2-15) that hold it
in place. Save the screws.
3. Mechanically secure the flexible conduit to the electrical conduit
access note (figure 2-15). (See Canadian Wiring Considerations
below.)
4. The terminal block and ground connection are near the left side of the
rear opening. The unit has either a three terminal block for 3 wire
DELTA connection, or a four terminal block for 4 wire WYE
connection.
5. Refer to the connection diagrams in figure 2-16, and connect the wires
to the terminal block and ground connector accordingly.
6. Each steamer MUST be electrically grounded by the installer
7. All SteamCraft V's are wired for 3 phase only, and are not convertible
to single phase.
8. If no further work is required inside the SteamCraft V, secure the rear
panel in place using six mounting screws (figure 2-15).
CET-16 Service Manual
Printed 4/90
Page 17
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Steamcraft v cet-16

Table of Contents